CHECK FORWARD RECOGNITION CAMERA
DTCs may be output when connectors are disconnected during inspection. Therefore, be sure to clear the DTCs using the GTS once the inspection has been completed.
Do not apply excessive force to the forward recognition camera connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| V6-1 (HTR) - V6-10 (GND) | LA-B - LA*1
LA-B - W-B*2 |
Forward recognition hood operation signal | Power switch on (IG), forward recognition hood not operating | 11 to 14 V |
| Power switch on (IG), forward recognition hood operating | Below 1 V | |||
| V6-7 (IGB) - V6-10 (GND) | LA-P - LA*1
LA-P - W-B*2 |
Power source | Power switch on (IG) | 11 to 14 V |
| Power switch off | Below 1 V | |||
| V6-10 (GND) - Body ground | LA - Body ground*1
W-B - Body ground*2 |
Ground | Always | Below 1 Ω |
*1: Through No. 29 Junction Connector
*2: Not through No. 29 Junction Connector