With the roof panel No.6 removed.
REMOVAL
| Symbol Meaning | |
|---|---|
|
Remove Weld Points |
|
Cut and Join Location |
*a in illustration above indicates where the adhesive is located.
Roughly cut open the panel so that the adhesive can be reached. Cut through the adhesive with a cut chisel to remove the panel.
In cases where the adhesive cannot be removed with a cut chisel, heat the adhesive with an industrial heater gun or gas burner taking care not to cause panel deformation by overheating.
| *A | for Glide Type | *B | LH |
| *b | mm (in.) | - | - |
| *A | for Folding Type | *B | LH |
| *b | mm (in.) | - | - |
| *A | RH | - | - |
| *b | mm (in.) | - | - |
INSTALLATION
| Symbol Meaning | |
|---|---|
|
Plug Weld |
|
Cut and Join Location |
|
Butt Weld |
Inspect the fitting of the related parts around the new parts before welding. This affects the appearance of the finish.
Temporarily install the new parts and measure each part of the new parts in accordance with the body dimension diagram. (See the body dimensions)
If the entire supply part is not needed, remove the part of the supply part that is needed.
Before temporarily installing the new parts, weld the NO.1 side panel, roof side panel outer and roof drip side channel center No.1 with the standard number of welding points.
Follow the welding conditions when welding *a to assure sufficient weld strength.
| Plug Diameter | Welding Wire Diameter | Plug Welding Hole Pitch | Shield Gas |
|---|---|---|---|
| 4 mm (0.16 in.) | 0.6 mm (0.02 in.) | 25 mm (0.98 in.) | Metal active gas (Ar 80% + CO2 20%) |
| 5 mm (0.20 in.) | 0.8 mm (0.03 in.) | 30mm (1.18 in.) |
Apply adhesive (3MTM AutomixTM Panel Bonding Adhesive #8115) to the area indicated by *b in the illustration.
Apply a light coat of adhesive around the plug welding points.
Apply enough adhesive to the panels.
After welding, apply body sealer to the corresponding parts. (See the painting / coating)
After applying the top coat, apply anti-rust agent to the internal panel portion of the closed section structural weld points.
Inspect the fitting of the related parts around the new parts before welding. This affects the appearance of the finish.
Temporarily install the new parts and measure each part of the new parts in accordance with the body dimension diagram. (See the body dimensions)
If the entire supply part is not needed, remove the part of the supply part that is needed.
Before temporarily installing the new parts, weld the front body pillar upper outer and roof side panel outer with the standard number of welding points.
Follow the welding conditions when welding *a to assure sufficient weld strength.
| Plug Diameter | Welding Wire Diameter | Plug Welding Hole Pitch | Shield Gas |
|---|---|---|---|
| 4 mm (0.16 in.) | 0.6 mm (0.02 in.) | 25 mm (0.98 in.) | Metal active gas (Ar 80% + CO2 20%) |
| 5 mm (0.20 in.) | 0.8 mm (0.03 in.) | 30mm (1.18 in.) |
Apply adhesive (3MTM AutomixTM Panel Bonding Adhesive #8115) to the area indicated by *b in the illustration.
Apply a light coat of adhesive around the plug welding points.
Apply enough adhesive to the panels.
After welding, apply body sealer to the corresponding parts. (See the painting / coating)
After applying the top coat, apply anti-rust agent to the internal panel portion of the closed section structural weld points.
| *A | LH | - | - |
| *1 | NO.1 SIDE PANEL | *2 | ROOF SIDE PANEL OUTER |
| *3 | Plug Welding Hole Center | - | - |
| *c | mm (in.) | - | - |
| *A | LH | - | - |
| *1 | ROOF SIDE PANEL OUTER | *2 | ROOF DRIP SIDE CHANNEL CENTER NO.1 |
| *A | for Glide Type | *B | LH |
| *A | for Folding Type | *B | LH |
| *A | RH | - | - |
| *1 | FRONT BODY PILLAR UPPER OUTER | *2 | ROOF SIDE PANEL OUTER |
| *3 | Plug Welding Hole Center | - | - |
| *c | mm (in.) | - | - |
| *A | RH | - | - |