Refer to the TOYOTA Repair Manual for adjustment method.
Vehicle Exterior > DOOR / HATCH
INSPECT FRONT DOOR PANEL SUB-ASSEMBLY RH
Check that the clearance measurements of areas A to E are within the standard ranges.
| Area | Measurement Condition | Specified Condition |
|---|---|---|
| A | 2 Coat Application | 4.3 to 7.3 mm (0.169 to 0.287 in.) |
| 4 Coat Application | 4.2 to 7.2 mm (0.165 to 0.283 in.) | |
| 2 Coat Application + Black Out Tape | 4.0 to 7.0 mm (0.157 to 0.276 in.) | |
| 4 Coat Application + Black Out Tape | 3.9 to 6.9 mm (0.154 to 0.272 in.) | |
| B | 2 Coat Application | 3.2 to 6.2mm (0.126 to 0.244 in.) |
| 4 Coat Application | 3.1 to 6.1mm (0.122 to 0.240 in.) | |
| 2 Coat Application + Black Out Tape | 2.9 to 5.9mm (0.114 to 0.232 in.) | |
| 4 Coat Application + Black Out Tape | 2.8 to 5.8mm (0.110 to 0.228 in.) | |
| C | 2 Coat Application | 4.4 to 7.4 mm (0.173 to 0.291 in.) |
| 4 Coat Application | 4.3 to 7.3 mm (0.169 to 0.287 in.) | |
| 2 Coat Application + Black Out Tape | 4.1 to 7.1 mm (0.161 to 0.280 in.) | |
| 4 Coat Application + Black Out Tape | 4.0 to 7.0 mm (0.157 to 0.276 in.) | |
| D | 2 Coat Application | 3.7 to 8.7 mm (0.146 to 0.343 in.) |
| 4 Coat Application | 3.6 to 8.6 mm (0.142 to 0.339 in.) | |
| 2 Coat Application + Black Out Tape | 3.4 to 8.4 mm (0.134 to 0.331 in.) | |
| 4 Coat Application + Black Out Tape | 3.3 to 8.3 mm (0.130 to 0.327 in.) | |
| E | 2 Coat Application | -0.9 to 4.1 mm (0.035 to 0.161 in.) |
| 4 Coat Application | -1.0 to 4.0 mm (0.039 to 0.157 in.) | |
| 2 Coat Application + Black Out Tape | -1.2 to 3.8 mm (0.047 to 0.149 in.) | |
| 4 Coat Application + Black Out Tape | -1.3 to 3.7 mm (0.051 to 0.146 in.) |
Centering bolts are used to mount the door hinge to the vehicle body and door. The door cannot be adjusted with the centering bolts on. Substitute the centering bolts for standard bolts when making adjustments.
INSPECT CENTER DOOR PANEL (for Glide Type)
Check that the clearance measurements of areas A to C are within the standard range.
| Area | Measurement Condition | Specified Condition |
|---|---|---|
| A | 2 Coat Application | 6.6 to 12.6 mm (0.260 to 0.496 in.) |
| 4 Coat Application | 6.5 to 12.5 mm (0.256 to 0.492 in.) | |
| B | 2 Coat Application | 13.4 to 17.4mm (0.528 to 0.685 in.) |
| 4 Coat Application | 13.4 to 17.4mm (0.528 to 0.685 in.) | |
| C | 2 Coat Application | 13.4 to 17.4mm (0.528 to 0.685 in.) |
| 4 Coat Application | 13.3 to 17.3mm (0.524 to 0.681 in.) |
INSPECT CENTER DOOR PANEL SUB-ASSEMBLY (for Folding Type)
Check that the clearance measurements of areas A to E are within the standard range.
| Area | Measurement Condition | Specified Condition |
|---|---|---|
| A | 2 Coat Application | 5.5 to 8.5 mm (0.216 to 0.335 in.) |
| 4 Coat Application | 5.4 to 8.4 mm (0.213 to 0.331 in.) | |
| B | 2 Coat Application | 1.3 to 4.3mm (0.051 to 0.169 in.) |
| 4 Coat Application | 1.2 to 4.2mm (0.047 to 0.165 in.) | |
| C | 2 Coat Application | 12.1 to 15.1 mm (0.476 to 0.594 in.) |
| 4 Coat Application | 12.1 to 15.1 mm (0.476 to 0.594 in.) | |
| D | 2 Coat Application | 21.6 to 24.6 mm (0.850 to 0.970 in.) |
| 4 Coat Application | 21.6 to 24.6 mm (0.850 to 0.970 in.) | |
| E | 2 Coat Application | 24.4 to 27.4 mm (0.960 to 0.079 in.) |
| 4 Coat Application | 24.3 to 27.3 mm (0.957 to 0.075 in.) |
INSPECT AUTO CENTER DOOR (for Glide Type)
Check that the clearance measurements of areas A to I are within the standard range.
| Area | Specified Condition | Area | Specified Condition |
|---|---|---|---|
| A | 6.55 to 12.55 mm (0.258 to 0.494 in.) | B | 13.2 to 17.2 mm (0.520 to 0.677 in.) |
| C | -2.0 to 2.0 mm (-0.0787 to 0.0787 in.) | D | 13.2 to 17.2 mm (0.520 to 0.677 in.) |
| E | -2.0 to 2.0 mm (-0.0787 to 0.0787 in.) | F | 13.2 to 17.2 mm (0.520 to 0.677 in.) |
| G | -2.0 to 2.0 mm (-0.0787 to 0.0787 in.) | H | 13.2 to 17.2 mm (0.520 to 0.677 in.) |
| I | -2.0 to 2.0 mm (-0.0787 to 0.0787 in.) | - | - |
INSPECT BACK DOOR PANEL SUB-ASSEMBLY
Check that the clearance measurements of areas A to H are within the standard range.
| Area | Specified Condition | Area | Specified Condition |
|---|---|---|---|
| A | 4.5 to 7.5 mm (0.177 to 0.296 in.) | B | -1.5 to 1.5 mm (-0.059 to 0.059 in.) |
| C | 4.5 to 7.5 mm (0.177 to 0.296 in.) | D | -1.5 to 1.5 mm (-0.059 to 0.059 in.) |
| E | 4.5 to 7.5 mm (0.177 to 0.296 in.) | F | -1.5 to 1.5 mm (-0.059 to 0.059 in.) |
| G | 7.2 to 12.2 mm (0.283 to 0.480 in.) | H | 7.5 to 12.5 mm (0.295 to 0.492 in.) |
INSPECT BACK DOOR PANEL SUB-ASSEMBLY RH (for Double Swing Out Type)
Check that the clearance measurements of areas A to F are within the standard range.
| Area | Specified Condition | Area | Specified Condition |
|---|---|---|---|
| A | 3.9 to 8.9 mm (0.154 to 0.350 in.) | B | 2.5 to 9.5 mm (0.098 to 0.374 in.) |
| C | -3.4 to 3.6 mm (-0.134 to 0.142 in.) | D | 4.5 to 7.5 mm (0.177 to 0.295 in.) |
| E | -1.4 to 1.6 mm (0.055 to 0.063 in.) | F | 7.5 to 13.5 mm (0.295 to 0.531 in.) |
INSPECT BACK DOOR PANEL SUB-ASSEMBLY LH (for Double Swing Out Type)
Check that the clearance measurements of areas A to H are within the standard range.
| Area | Specified Condition | Area | Specified Condition |
|---|---|---|---|
| A | 3.9 to 8.9 mm (0.154 to 0.350 in.) | B | 3.0 to 11.0 mm (0.118 to 0.433 in.) |
| C | -4.0 to 4.0 mm (-0.157 to 0.157 in.) | D | 2.5 to 9.5 mm (0.098 to 0.374 in.) |
| E | -3.5 to 3.5 mm (-0.138 to 0.138 in.) | F | 4.5 to 7.5 mm (0.177 to 0.295 in.) |
| G | -1.4 to 1.6 mm (0.055 to 0.063 in.) | H | 7.5 to 13.5 mm (0.295 to 0.531 in.) |
INSPECT BACK DOOR PANEL SUB-ASSEMBLY RH (for Emergency Door)
Check that the clearance measurements of areas A to F are within the standard range.
| Area | Specified Condition | Area | Specified Condition |
|---|---|---|---|
| A | 3.9 to 8.9 mm (0.154 to 0.350 in.) | B | 2.5 to 9.5 mm (0.098 to 0.374 in.) |
| C | -3.4 to 3.6 mm (-0.134 to 0.142 in.) | D | 4.5 to 7.5 mm (0.177 to 0.295 in.) |
| E | -1.4 to 1.6 mm (0.055 to 0.063 in.) | F | 7.5 to 13.5 mm (0.295 to 0.531 in.) |
INSPECT BACK DOOR PANEL SUB-ASSEMBLY LH (for Emergency Door)
Check that the clearance measurements of areas A to H are within the standard range.
| Area | Specified Condition | Area | Specified Condition |
|---|---|---|---|
| A | 3.9 to 8.9 mm (0.154 to 0.350 in.) | B | 3.0 to 11.0 mm (0.118 to 0.433 in.) |
| C | -4.0 to 4.0 mm (-0.157 to 0.157 in.) | D | 2.5 to 9.5 mm (0.098 to 0.374 in.) |
| E | -3.5 to 3.5 mm (-0.138 to 0.138 in.) | F | 4.5 to 7.5 mm (0.177 to 0.295 in.) |
| G | -1.4 to 1.6 mm (0.055 to 0.063 in.) | H | 7.5 to 13.5 mm (0.295 to 0.531 in.) |