CONSTRUCTION
An air-cooled type fuel cooler is provided. The fuel cooler, which is located in the fuel return path, cools the return fuel that has reached a high temperature as a result of the pumping of the supply pump. This prevents the reduction in fuel viscosity that is caused by the rise in fuel temperature, and improves the reliability of the fuel system.
The fuel passage and cooling fins in the cooling core of the fuel cooler have been molded together in order to reduce both the number of parts and the weight.
| *a | From Engine | *b | To Fuel Tank |
| *c | Front of Vehicle | *d | A-A Cross Section |