Home › Engine / Hybrid System › 1HZ (COOLING) › COOLING SYSTEM › from 2019.08
NM2850E _51 Engine / Hybrid System _074193 1HZ COOLING _0361405 COOLING SYSTEM DE DETAILS F

1HZ COOLING  COOLING SYSTEM  DETAILS  SUB RADIATOR  


CONSTRUCTION


a.

The sub-radiator has been adopted to improve the engine's cooling efficiency. It consists of the double row type sub-radiator which dissipates engine coolant heat, the electric cooling fan, which forces air through the sub-radiator, and the water temperature switch which controls the operation of the cooling fan according to the coolant temperature. As illustrated below, the cooling circuit of the sub-radiator is parallel to the main radiator, so that coolant reaches the main radiator at the same time as the sub-radiator.

Sub-radiator
W144061C01
1.771,3.198 2.188,2.781 true 3.302,3.25 3.26,2.625 true 4.615,2.521 4.24,1.573 true 1.625,3.219 1.938,3.375 0.313,0.156 10 false *1 3.25,3.292 3.563,3.448 0.313,0.156 10 false *2 4.583,2.563 4.896,2.719 0.313,0.156 10 false *3
*1 Water Temperature Switch *2 Sub-radiator
*3 Electrical Cooling fan - -


Cooling Circuit
W140911