CONSTRUCTION
The function of the common rail assembly is to store the fuel that has been pressurized by the injection or supply pump assembly.
The common rail assembly is provided with a fuel pressure sensor, pressure discharge valve and fuel pressure limiter.
The fuel pressure sensor outputs a signal that represents the fuel pressure in the common rail assembly to the ECM in order to constantly regulate the fuel at an optimal pressure.
The valve opening pressure of the pressure limiter has been optimized in accordance with the increase in the pump pressure.
The pressure discharge valve regulates the fuel pressure. In the pressure discharge valve, the plunger opens and closes in accordance with the actuation signals from the ECM. Thus, it regulates pressure by releasing excess pressure from the common rail assembly. In addition, it has a pressure reduction function in case of emergency.
| *1 | Fuel Pressure Limiter | *2 | Fuel Pressure Sensor |
| *3 | Common Rail Assembly | *4 | Pressure Discharge Valve |
|
From Injection or Supply Pump Assembly |
|
To Injector Assembly |