FUNCTION
A DPF (Diesel Particulate Filter) catalytic converter, which contains a filter with catalyst for capturing PM (Particulate Matter), is used in the center pipe in order to comply with the emission regulations.
In the DPF system, the ECM precisely controls the common-rail system, and effects DPF control to burn the PM that is captured in the filter. As a result, this system realizes a stable PM reduction performance even when the exhaust gas temperature is low.
The ECM judges the DPF catalytic converter condition based on injection volume, injection timing, and signals from the mass air flow meter sensor sub-assembly, engine coolant temperature sensor, two exhaust gas temperature sensors and differential pressure sensor. When the filter in the DPF catalytic converter captures a predetermined amount of PM, it automatically burns the captured PM. This prevents an abnormal accumulation of PM, allowing the DPF catalytic converter to operate normally.
OPERATION
When the exhaust gas temperature is high, such as when driving at high speeds, the filter in the DPF catalytic converter reaches a temperature that burns the PM, allowing the PM to burn naturally.
When the exhaust gas temperature is low, it becomes possible to raise the temperature of the filter in the DPF catalytic converter by injecting fuel during the exhaust stroke of the cylinder. Thus, even when the exhaust gas temperature is low, this function raises the temperature of the filter to a temperature (approx. 600°C) that effectively burns the accumulated PM.
During normal driving, this function switches automatically to the cleaning mode approximately every 200 km*. The cleaning mode does not affect driving. If the cleaning mode operates while the engine is idling, the idle speed increases, causing the exhaust retarder to operate. Thus, the cleaning of the filter might not be completed, depending on the driving conditions. The DPF indicator light in the combination meter will flash to indicate that the cleaning has not been completed. When this happens, the driver must press the DPF switch to effect forced cleaning. If the driver does not attend to it even if the DPF indicator light in the combination meter flash, the amount of PM accumulated in the DPF catalytic converter will increase. Then, the ECM will inform the driver by illuminating the check engine warning light and sounding the buzzer.
*: This distance varies depending on the driving conditions.