The vehicle speed sensor outputs a 4 pulse signal for every revolution of the rotor shaft, which is rotated by the transmission output shaft via the driven gear. After this signal is converted into a more precise rectangular waveform by the waveform shaping circuit inside the combination meter, it is then transmitted to the ECM. The ECM determines the vehicle speed based on the frequency of these pulse signals.
| DTC No. | DTC Detection Condition | Suspected Area |
|---|---|---|
| P0500/42 | While vehicle is being driven, no vehicle speed sensor signal to ECM | ·
Open or short in speed sensor circuit ·
Vehicle speed sensor ·
Combination meter ·
ECM |
Read freeze frame data using an intelligent tester. Freeze frame data records the engine conditions when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Drive the vehicle and check whether the operation of the speedometer in the combination meter is normal.
Speedometer operation is normal.
The vehicle speed sensor is operating normally if the speedometer reading is normal.
If the speedometer does not operate, check it by following the procedure described in speedometer malfunction.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Move the transmission gear select lever to the neutral position.
Jack up the vehicle.
Turn the ignition switch to ON.
Measure the voltage of the ECM connectors as the wheel is turned slowly.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A51-9 (SPD) - B76-24 (E1) | Ignition switch ON | Voltage is generated intermittently |
| *1 | Component with harness connected
(ECM) |
| *2 | Wheel Turned |
The output voltage should fluctuate up and down (as shown in the illustration) when the wheel is turned slowly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the combination meter connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| J1-6 (+S) - A51-9 (SPD) | Always | Below 1 Ω |
| J1-6 (+S) or A51-9 (SPD) - Body ground | Always | 10 kΩ or higher |
Reconnect the ECM connector.
Reconnect the combination meter connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG