The Automatic Transmission Fluid (ATF) temperature sensor converts the ATF temperature into a resistance value which is input into the Transmission Control Module (TCM).
The TCM applies a voltage to the temperature sensor.
The sensor resistance changes with the ATF temperature.
One terminal of the sensor is grounded so that the sensor resistance and voltage decrease as the temperature becomes higher.
The TCM calculates the ATF based on the voltage signal.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| 38 | ATF temperature sensor resistance is less than 79 Ω for 0.5 sec. or more (1 trip detection logic) | ·
Short in ATF temperature sensor circuit ·
ATF temperature sensor ·
TCM |
| ATF temperature sensor resistance is more than 156 kΩ for 15 minutes or more after the engine starts
DTC is detected for 0.5 sec. or more (1 trip detection logic) |
·
Open in ATF temperature sensor circuit ·
ATF temperature sensor ·
TCM |
ATF temperature sensor converts ATF temperature to an electrical resistance value. Based on the resistance, the TCM determines the ATF temperature, and the TCM detects an open or short in the ATF temperature circuit. If the resistance value of the ATF temperature is less than 79 Ω or more than 156 kΩ, the TCM interprets this as a fault in the ATF sensor or wiring. The TCM will blinks the O/D OFF indicator light and store the DTC.
Disconnect the NO.1 ATF temperature sensor connector from the transmission.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Always | 79 to 156 kΩ |
| 1 - Body ground | Always | 10 kΩ or higher |
| 2 - Body ground | Always | 10 kΩ or higher |
| *1 | Component without harness connected:
(NO.1 ATF Temperature Sensor) |
If the resistance is not within the specified range for either of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.
| ATF Temperature | Specified Condition |
|---|---|
| 20°C (68°F) | 10.3 to 13.9 kΩ |
| 110°C (230°F) | 0.68 to 0.88 kΩ |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the TCM connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A61-15 (THO) - B78-20 (E2) | Always | 79 to 156 kΩ |
| A61-15 (THO) - Body ground | Always | 10 kΩ or higher |
| B78-20 (E2) - Body ground | Always | 10 kΩ or higher |
| *1 | Rear view of wire harness connector:
(to TCM) |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (OT+) - 5 (OT-) | 10°C (50°F) | 5.80 to 7.09Ω |
| 1 (OT+) - 5 (OT-) | 110°C (230°F) | 0.231 to 0.263Ω |
| *1 | Component without harness connected:
(Transmission Wire) |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the TCM connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B78-6 (OIL2) - B78-20 (E2) | 10°C (50°F) | 5.80 to 7.09Ω |
| B78-6 (OIL2) - Body ground | Always | 10 kΩ or higher |
| *1 | Rear view of wire harness connector:
(to TCM) |
| Proceed to |
|---|
| OK |
| NG |
OK
NG