22100
1.INSPECT SUPPLY PUMP ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (SCV+) - 2 (SCV-) | 20°C (68°F) | 1.9 to 2.7 Ω |
The temperature indicated in "Condition" refers to the temperature of the suction control valve.
If the result is not as specified, replace the supply pump assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (E2) - 2 (THF) | 20°C (68°F) | 2.32 to 2.59 kΩ |
| 1 (E2) - 2 (THF) | 80°C (176°F) | 0.310 to 0.326 kΩ |
|
If the result is not as specified, replace the supply pump assembly. |
|
| *a | Resistance |
| *b | Temperature |
| *c | Acceptable Range |