1.INITIAL CONDITIONS
Engine at reach normal operating temperature
Air cleaner installed
All vacuum lines properly connected
Valve clearance set correctly
Injection timing set correctly
Transmission in N range
Idle speed set correctly
2.CONNECT TACHOMETER
3.ADJUST AIR CONDITIONER IDLE-UP SETTING SPEED
Start the engine.
A/C switches ON.
Disconnect the vacuum hose from the idle-up actuator.
Apply vacuum to the idle-up actuator.
Race the engine to 2,500 rpm for a few seconds, release the throttle and check the idle-up setting speed.
950 rpm
Adjust the idle-up setting speed by turning the IDLEUP SETTING SPEED ADJUSTING SCREW.
Race the engine to 2,500 rpm for a few seconds, release the throttle and recheck the A/C idle-up setting speed.
Reconnect the vacuum hose to the idle-up actuator.