Home › Engine / Hybrid System › 1HZ COOLING › RADIATOR
RM2850E _51 Engine / Hybrid System _073153 1HZ COOLING _0355960 RADIATOR A

1HZ COOLING  RADIATOR  RADIATOR INSPECTION  


PROCEDURE

Hide 1.INSPECT RADIATOR CAP

a.
A422301

Using a radiator cap tester, pump the tester and measure the relief valve opening pressure.

Standard opening pressure:

0.75 - 1.05 kg/cm2 (10.7 - 14.9 psi, 74 - 103 kPa)


Minimum opening pressure:

0.6 kg/cm2 (8.5 psi, 59 kPa)


If the opening pressure is less than minimum, replace the radiator cap.


Hide 2.INSPECT COOLING SYSTEM FOR LEAKS

a.
A422302

Fill the radiator with coolant and attach a radiator cap tester.


b.

Warm up the engine.


c.

Pump it to 1.2 kg/cm2 (17.1 psi, 118 kPa), check that pressure does not drop.

If the pressure drops, check for leaks the hoses, radiator or water pump. If no external leaks are found, check the heater core, cylinder block and head.