23670
1.INSPECT INJECTOR ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 0.85 to 1.05 Ω |
| *a | Component without harness connected (Injector Assembly) |
If the result is not as specified, replace the injector.