1.REMOVE FUEL HEATER
2.INSPECT FUEL HEATER
Apply a vacuum of 34.7 +/- 5.3 kPa (260 +/- 40 mmHg, 10.24 +/- 1.57 in.Hg) or more to the vacuum switch port.
Using an ohmmeter, measure the resistance between terminal 1 and the switch body.
At 20°C (68° F): 0.5 - 2.0 Ω
If the resistance is not as specified, replace the fuel heater and vacuum switch assembly.
3.INSPECT VACUUM SWITCH
Inspect switch continuity
Using an ohmmeter, check that there is no continuity between terminal 1 and the switch body.
If continuity is not as specified, replace the fuel heater and vacuum switch assembly.
Inspect switch operation
Apply a vacuum of 34.7 +/- 5.3 kPa (260 +/- 40 mmHg, 10.24 +/- 1.57 in.Hg) or more to the vacuum switch port.
Using an ohmmeter, check that there is continuity between terminal 1 and the switch body.
If operation is not as specified, replace the fuel heater and vacuum switch assembly.
4.REINSTALL FUEL HEATER