Home › Engine / Hybrid System › 14B (FUEL) › FUEL INJECTION NOZZLE › 2017.01–2019.08
RM2850E _51 Engine / Hybrid System _073168 14B FUEL _0356040 FUEL INJECTION NOZZLE A

14B FUEL  FUEL INJECTION NOZZLE  INJECTION NOZZLES TEST  


PROCEDURE

Hide 1. INJECTION PRESSURE TEST

a.
A424197

Install the injection nozzle to the injection nozzle hand tester and bleed air from the union nut.

CAUTION:

Do not place your finger over the nozzle injection hole.



b.

Pump the tester handle a few times as fast as possible to discharge the carbon from the injection hole.


c.
A424198

Pump the tester handle slowly and observe the pressure gauge.


d.

Read the pressure gauge just as the injection pressure begins to drop.

Opening pressure:
New nozzle:

19,610 - 20,590 kPa

(200 - 210 kgf/cm2, 2,840 - 2,990 psi)

Reused nozzle:

17,650 - 20,590 kPa

(180 - 210 kgf/cm2, 2,560 - 2,990 psi)


HINT:

Proper nozzle operation can be determined by a swishing sound.


If the opening pressure is not as specified, disassemble the nozzle holder and change the adjusting shim on the top of the pressure spring.

Adjusted opening pressure:

17,650 - 20,590 kPa

(180 - 210 kgf/cm2, 2,580 - 2,990 psi)


Adjusting shim thickness:
mm (in.)
0.700 (0.0276) 1.125 (0.0443) 1.425 (0.0561)
0.750 (0.0295) 1.150 (0.0453) 1.450 (0.0571)
0.800 (0.0315) 1.175 (0.0463) 1.475 (0.0581)
0.850 (0.0335) 1.200 (0.0472) 1.500 (0.0591)
0.900 (0.0354) 1.225 (0.0462) 1.550 (0.0610)
0.950 (0.0374) 1.250 (0.0492) 1.600 (0.0630)
0.975 (0.0384) 1.275 (0.0502) 1.650 (0.0650)
1.000 (0.0394) 1.300 (0.0512) 1.700 (0.0669)
1.025 (0.0404) 1.325 (0.0522) 1.750 (0.0689)
1.050 (0.0413) 1.350 (0.0531) 1.800 (0.0709)
1.075 (0.0423) 1.375 (0.0541) -
1.100 (0.0433) 1.400 (0.0551) -


HINT:
·

Varying the adjusting shim thickness by 0.025 mm (0.0010 in.) changes the injection pressure by about 373 kPa (3.8 kgf/cm2, 54 psi).

·

Only one adjusting shim should be used.




e.

There should be no dripping after injection.


Hide 2. LEAKAGE TEST

a.
A424199

While maintaining pressure at about 981 - 1,961 kPa (10 - 20 kgf/cm2, 142 - 284 psi) below opening pressure (adjust by tester handle), check that there is no dripping for 10 seconds from the injection hole or around the retaining nut.

If the nozzle drips within 10 seconds, replace or clean and overhaul the nozzle assembly.


Hide 3. SPRAY PATTERN TEST

a.
A424200

The injection nozzle should shudder at a certain pumping speed between 15 - 60 times (old nozzle) or 30 - 60 times (new nozzle) per minute.


b.

Check the spray pattern during shuddering.

If the spray pattern is not correct during shuddering, the nozzle must be replaced or cleaned.