1.DISASSEMBLE INJECTION NOZZLES
Using a 14 mm deep socket wrench, unscrew the nozzle holder retaining nut.
When disassembling the nozzle, be careful not to drop the inner parts.
Remove the pressure spring, adjusting shim, pressure pin, pin, distance piece and the nozzle assembly.