16331A
1.INSPECT THERMOSTAT
The thermostat is numbered with the valve opening temperature.
Immerse the thermostat in water and gradually heat the water.
Check the valve opening temperature.
80 - 84°C (176 - 183°F)
If the valve opening temperature is not as specified, replace the thermostat.
Check the valve lift.
10 mm (0.39 in.) or more at 95°C (203° F)
If the valve lift is not as specified, replace the thermostat.
Check that the valve spring is tight when the thermostat is fully closed.
If not closed, replace the thermostat.