1.REMOVE MAGNETIC SWITCH END COVER
Remove the nut, disconnect the lead wire from terminal C and remove the plate washer.
Remove the 3 bolts and end cover from the magnetic switch assembly.
Remove these parts from the magnetic switch assembly:
Plunger
Return spring
2.INSPECT CONTACT PLATE FOR WEAR
Using vernier calipers, measure the contact plate for depth of wear.
1.6 mm (0.063 in.)
If the depth of wear is greater than the maximum, replace the contact plate.
3.REMOVE TERMINAL KIT PARTS
Using SST, remove the nut and washer.
Remove these parts from the magnetic switch assembly (Terminal C):
Terminal insulator outer
Terminal bolt
Contact plate
Terminal insulator inner
Remove these parts from the magnetic switch assembly (Terminal 30):
Terminal insulator outer
Packing
O-ring
Contact plate and terminal bolt
Terminal insulator inner
Insulation paper
4.REINSTALL TERMINAL KIT PARTS (Terminal 30)
Insert the insulation paper between the coil and housing.
Install the insulation paper facing the correct direction as shown in the illustration.
Install these parts to the magnetic switch assembly:
Install the terminal insulator inner in the direction as shown in the illustration.
Terminal insulator inner
Contact plate
Terminal bolt
Install the O-ring on the terminal bolt.
Place the packing to the terminal insulator outer, and install it to the terminal.
Match the protrusion of the insulator with the indentation of the housing.
Install the washer and nut, temporarily tighten the nut.
5.REINSTALL TERMINAL KIT PARTS (Terminal C)
Install these parts to the magnetic switch assembly:
Install the terminal insulator inner in the same direction as terminal 30.
Terminal insulator inner
Contact plate
Terminal bolt
Terminal insulator outer
Install the washer and nut, temporarily tighten the nut.
6. TIGHTEN TERMINAL NUT
Put a wood block on the contact plate and press it down with a hand press.
20 x 37 x 40 mm (0.79 x 1.46 x 1.57 in.)
981 N (100 kgf, 221 lbf)
Check the diameter of the hand press ram. Then calculate the gauge pressure of the press when 981 N (100 kgf, 221 lbf) of force is applied.
If the contact plate is not pressed down with the specified pressure, the contact plate may tilt due to coil deformation or the tightening of the nut.
Using SST, tighten the nut to the specified torque.
30 N*m (305 kgf*cm, 22 ft.*lbf)
If the nut is over tightened, it may cause cracks on the inside of the insulator.
7.CLEAN CONTACT SURFACES OF CONTACT PLATE AND PLUNGER
Clean the contact surfaces of the remaining contact plate and plunger with a dry shop rag.
8.REINSTALL MAGNETIC SWITCH END COVER
Install these parts to the magnetic switch assembly:
Return spring
Plunger
Install the gasket and magnetic switch end cover with the 3 bolts.
3.6 N*m (37 kgf*cm, 32 in.*lbf)
Place the plate washer on terminal C, connect the lead wire to it and install the nut.
21 N*m (215 kgf*cm, 16 ft.*lbf)