These tests must be performed within 3 to 5 seconds to avoid burning out the coil.
1.PERFORM PULL-IN TEST
Disconnect the field coil lead wire from terminal C.
Connect the battery to the magnetic switch as shown. Check that the clutch pinion gear moves outward.
2.PERFORM HOLD-IN TEST
With battery connected as above with the clutch pinion gear out, disconnect the negative (-) lead from terminal C. Check that the pinion gear remains out.
3.INSPECT CLUTCH PINION GEAR RETURN
Disconnect the negative (-) lead from the switch body.
Check that the clutch pinion gear returns inward.
4.PERFORM NO-LOAD PERFORMANCE TEST
Connect the battery and ammeter to the starter as shown.
Check that the starter rotates smoothly and steadily with the pinion gear moving out. Check that the ammeter shows the specified current.
2.5 kW: 180A or less at 11.0V
4.5 kW: 90A or less at 23.0V