1.INSPECT RADIATOR CAP SUB-ASSEMBLY
Measure the valve opening pressure.
If there are water stains or foreign matter on rubber packings 1, 2 or 3, clean the parts with water and finger scouring.
Check that rubber packings 1, 2 and 3 are not deformed, cracked or swollen.
Check that rubber packings 3 and 4 are not stuck together.
Apply engine coolant to rubber packings 2 and 3 before using the radiator cap tester.
When using the cap tester, tilt it to more than 30 degrees.
| *1 | Radiator Reservoir Cap |
| *a | Radiator Cap Tester |
| *b | More than 30° |
Pump the cap tester several times, and check the maximum pressure*1.
1 pump per second.
*1: Even if the cap cannot maintain the maximum pressure it is not a defect.
| Item | Specified Condition |
|---|---|
|
If the maximum pressure is less than the specified pressure for the minimum standard value, replace the radiator cap sub-assembly. |
|
| Standard value (for brand new cap) | 93 to 123 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi) |
| Minimum standard value (after using cap) | 78 kPa (0.8 kgf/cm2, 11.4 psi) |