Home › Steering › POWER ASSIST SYSTEMS › VANE PUMP(for N04C Series Engine)
RM2850E _55 Steering _073197 POWER ASSIST SYSTEMS _0356230 VANE PUMP(for N04C Series Engine) G

POWER ASSIST SYSTEMS  VANE PUMP(for N04C Series Engine)  INSPECTION  


PROCEDURE

Hide 1.INSPECT OIL CLEARANCE

a.
C318846

Using a micrometer and a caliper gauge, measure the oil seal clearance.

Maximum clearance:

0.07 mm (0.0028 in.)


HINT:

If the result is more than the maximum, replace the vane pump assembly.



Hide 2.INSPECT VANE PUMP ROTOR AND VANE PUMP PLATES CLEARANCE

a.
C101977E19
2.542,0.313 2.896,0.521 0.354,0.208 10 false *a

Using a micrometer, measure the thickness of the vane pump plates.

Standard thickness:

1.405 to 1.411 mm (0.05531 to 0.05555 in.)


HINT:

If the result is not as specified, replace the vane pump assembly.


Text in Illustration
*a Thickness


b.
C101978

Using a feeler gauge, measure the clearance between the side face of the vane pump rotor groove and the vane pump plate.

Maximum clearance:

0.03 mm (0.0012 in.)


HINT:

If the clearance exceeds the maximum, replace the vane pump assembly with a new one.



Hide 44330 3.INSPECT FLOW CONTROL VALVE

a.

Check the flow control valve and the hole of the vane pump front housing for scratches.


b.

Coat the flow control valve with power steering fluid.


c.

Insert the flow control valve into the vane pump front housing and check that it falls smoothly into the hole under its own weight.

NOTICE:

Do not damage the flow control valve or the hole in the vane pump front housing.


HINT:

If the flow control valve does not fall smoothly into the flow control valve hole, replace the vane pump assembly with a new one.



d.
C101979E02
2.086,1.57 2.228,1.747 0.142,0.177 10 A 2.051,0.292 2.198,0.462 0.147,0.17 10 B 0.484,0.779 0.64,0.935 0.156,0.156 10 C 2.808,0.756 2.95,0.931 0.142,0.175 10 D

Check the flow control valve for leakage.

i.

Close hole A.


ii.

Apply compressed air at 0.39 to 0.49 MPa (4 to 5 kgf/cm2, 57 to 71 psi) into hole B.


iii.

Confirm that the air does not flow out from hole C or D.

HINT:

If any leakage is found, replace the vane pump assembly with a new one.




Hide 44330A 4.INSPECT FLOW CONTROL VALVE COMPRESSION SPRING

a.

Using a vernier caliper, measure the free length of the flow control valve compression spring.

Minimum free length:

31.3 mm (1.232 in.)


HINT:

If the result is less than the minimum, replace the vane pump assembly with a new one.



Hide 44338 5.INSPECT PRESSURE PORT UNION

a.

Check the union seat in the pressure port union for any severe damage.

HINT:

If the union seat in the pressure port union is badly damaged, it could cause fluid leakage, so replace the vane pump assembly with a new one.