Home › Engine / Hybrid System › 1BZ-FPE (ENGINE MECHANICAL) › CO/HC › 2017.01–2021.01
RM2850E _51 Engine / Hybrid System _073200 1BZ-FPE ENGINE MECHANICAL _0356239 CO/HC G

1BZ-FPE ENGINE MECHANICAL  CO/HC  INSPECTION  


CAUTION / NOTICE / HINT

HINT:

This check is used only to determine whether or not the idle CO/HC complies with regulations.


PROCEDURE

Hide 1.INSTALLATION CONDITIONS

a.

Engine at normal operating temperature


b.

Air cleaner installed


c.

Air pipes and hoses of air induction system connected


d.

All accessories switched OFF


e.

All vacuum lines properly connected


f.

EFI system wiring connectors fully plugged


g.

Ignition timing checked correctly


h.

Transmission in neutral range


i.

Tachometer and CO/HC meter calibrated by hand


Hide 2.START ENGINE

Hide 3.RACE ENGINE AT 2,500 RPM FOR APPROX. 120 SECONDS

Hide 4.INSERT CO/HC METER TESTING PROBE AT LEAST 40 cm (1.3 ft) INTO TAILPIPE WHILE IDLING THE ENGINE

A422179

Hide 5.CHECK CO/HC CONCENTRATION AT IDLE

a.

Idle CO concentration: 0 - 1.0 %


b.

Idle HC concentration: Applicable local regulation


Hide 6. IF NOT AS SPECIFIED, ADJUST AIR FUEL RATIO

a.
A422180

Connect the positive (+) tester probe to VF1 terminal of the check connector and the negative (-) tester probe to E1 terminal.


b.

Warm up the heated oxygen sensor, maintaining the engine speed at 2,500 rpm for approx. 2 minutes.


c.

Using SST, short-circuit between terminals TE1 and E1 of the check connector.


d.

Maintaining the engine speed at 2,500 rpm, check that the tester indication changes between 0 and 5 V.

Standard:

More than 8 times of changes for 10 seconds



e.

Disconnect the short-circuit between terminals TE1 and E1.


f.
A422181

Measure the indicated voltage (VF voltage) at the idle speed.

Standard voltage:

2.5 +/- 0.9 V


If the voltage is not as specified, adjust the VF voltage within the specified value by turning the idle adjusting screw of the LPG regulator by 10° per second.

Reference:
VF voltage Condition Measures
0 V Air fuel ratio: Rich Turn the screw clockwise
5 V Air fuel ratio: Lean Turn the screw counterclockwise



g.

After racing the engine speed several times, check that the VF voltage is within the specified value.

If not, readjust it.