Home › Engine / Hybrid System › 1BZ-FPE (STARTING) › IGNITION SWITCH › 2017.01–2021.01
RM2850E _51 Engine / Hybrid System _073205 1BZ-FPE STARTING _0356280 IGNITION SWITCH G

1BZ-FPE STARTING  IGNITION SWITCH  INSPECTION  


PROCEDURE

Hide 84450 1.INSPECT IGNITION SWITCH ASSEMBLY

a.
A396342E01
1.615,3.385 1.99,2.469 1.99,2.469 2.125,2.469 true 1.854,3.385 2.115,2.719 2.115,2.719 2.25,2.719 true 1.375,3.396 1.073,2.594 1.073,2.594 0.917,2.594 true 1.198,3.406 0.938,2.854 0.938,2.854 0.781,2.854 true 1.208,3.646 1,4.083 1,4.083 0.844,4.083 true 1.427,4.188 1.427,3.635 true 1.823,4.198 1.823,3.646 true 0.083,0.073 0.396,0.271 0.313,0.198 10 false *a 1.615,0.198 1.927,0.396 0.313,0.198 10 false *d 2.354,0.448 2.667,0.646 0.313,0.198 10 false *e 0.896,0.448 1.208,0.646 0.313,0.198 10 false *c 0.385,1.51 0.698,1.708 0.313,0.198 10 false *b 2.208,2.396 2.635,2.594 0.427,0.198 10 false ACC 2.323,2.635 2.75,2.833 0.427,0.198 10 false ST1 0.677,2.5 1.104,2.698 0.427,0.198 10 false IG1 0.448,2.771 0.875,2.969 0.427,0.198 10 false AM1 1.365,4.24 1.792,4.438 0.427,0.198 10 false IG2 0.5,4.01 0.927,4.208 0.427,0.198 10 false AM2 1.729,4.24 2.156,4.438 0.427,0.198 10 false ST2

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
Between all terminals LOCK 10 kW or higher
4 (ACC) - 6 (AM1) ACC Below 1 W
4 (ACC) - 6 (AM1) ON Below 1 W
5 (IG1) - 6 (AM1)
11 (IG2) - 12 (AM2)
5 (IG1) - 6 (AM1) START Below 1 W
3 (ST1) - 6 (AM1)
11 (IG2) - 12 (AM2)
9 (ST2) - 12 (AM2)


Text in Illustration
*a Component without harness connected (Ignition Switch Assembly)
*b LOCK
*c ACC
*d ON
*e START

If the result is not as specified, replace the ignition switch assembly.