84450
1.INSPECT IGNITION SWITCH ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| Between all terminals | LOCK | 10 kW or higher |
| 4 (ACC) - 6 (AM1) | ACC | Below 1 W |
| 4 (ACC) - 6 (AM1) | ON | Below 1 W |
| 5 (IG1) - 6 (AM1) | ||
| 11 (IG2) - 12 (AM2) | ||
| 5 (IG1) - 6 (AM1) | START | Below 1 W |
| 3 (ST1) - 6 (AM1) | ||
| 11 (IG2) - 12 (AM2) | ||
| 9 (ST2) - 12 (AM2) |
| *a | Component without harness connected (Ignition Switch Assembly) |
| *b | LOCK |
| *c | ACC |
| *d | ON |
| *e | START |
If the result is not as specified, replace the ignition switch assembly.