Home › Vehicle Interior › AIR CONDITIONING › FRONT COOLING UNIT
RM2850E _58 Vehicle Interior _073207 AIR CONDITIONING _0356285 FRONT COOLING UNIT G

AIR CONDITIONING  FRONT COOLING UNIT  INSPECTION  


PROCEDURE

Hide 88625 1.INSPECT NO. 1 COOLER THERMISTOR

a.
E363281E01
0.333,1.344 0.333,0.75 0.333,0.75 0.563,0.75 false 1.365,2.969 1.927,2.969 false 1.906,0.25 2.26,0.448 0.354,0.198 10 false *a 0.625,0.667 0.979,0.865 0.354,0.198 10 false *b 0.333,1.719 0.729,1.917 0.396,0.198 10 false *d 1.99,2.875 2.344,3.073 0.354,0.198 10 false *c 1.969,4.271 2.365,4.469 0.396,0.198 10 false *e

Measure the resistance according to the value(s) in the table below.

Text in Illustration
*a Component without harness connected
(No. 1 Cooler Thermistor)
*b Sensing Portion
*c Acceptable Range
*d Resistance (kW)
*e Temperature (°C (°F))

Standard Resistance
Tester Connection Condition Specified Condition
1 - 2 -10°C (14°F) 7.40 to 9.20 kW
1 - 2 -5°C (23°F) 5.65 to 7.00 kW
1 - 2 0°C (32°F) 4.35 to 5.40 kW
1 - 2 5°C (41°F) 3.40 to 4.20 kW
1 - 2 10°C (50°F) 2.68 to 3.30 kW
1 - 2 15°C (59°F) 2.10 to 2.60 kW
1 - 2 20°C (68°F) 1.66 to 2.10 kW
1 - 2 25°C (77°F) 1.32 to 1.66 kW
1 - 2 30°C (86°F) 1.05 to 1.35 kW

NOTICE:
·

Touching the sensor even slightly may change the resistance value. Hold the sensor connector.

·

When measuring the resistance, the temperature of the sensor and the cooler thermistor must be the same.



HINT:

As the temperature increases, the resistance decreases (See the graph).

If the operation is not as specified, replace the No. 1 cooler thermistor.