1.INSPECT NO. 1 COOLER THERMISTOR
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(No. 1 Cooler Thermistor) |
| *b | Sensing Portion |
| *c | Acceptable Range |
| *d | Resistance (kW) |
| *e | Temperature (°C (°F)) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | -10°C (14°F) | 7.40 to 9.20 kW |
| 1 - 2 | -5°C (23°F) | 5.65 to 7.00 kW |
| 1 - 2 | 0°C (32°F) | 4.35 to 5.40 kW |
| 1 - 2 | 5°C (41°F) | 3.40 to 4.20 kW |
| 1 - 2 | 10°C (50°F) | 2.68 to 3.30 kW |
| 1 - 2 | 15°C (59°F) | 2.10 to 2.60 kW |
| 1 - 2 | 20°C (68°F) | 1.66 to 2.10 kW |
| 1 - 2 | 25°C (77°F) | 1.32 to 1.66 kW |
| 1 - 2 | 30°C (86°F) | 1.05 to 1.35 kW |
Touching the sensor even slightly may change the resistance value. Hold the sensor connector.
When measuring the resistance, the temperature of the sensor and the cooler thermistor must be the same.
As the temperature increases, the resistance decreases (See the graph).
If the operation is not as specified, replace the No. 1 cooler thermistor.