84170A
1.INSPECT NO. 1 ROOM LIGHT SWITCH ASSEMBLY
Inspect the No. 1 room light switch assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 4(+B) - 1(D) | No. 1 room light switch off | 10 kΩ or higher |
| No. 1 room light switch on | Below 1 Ω |
If the result is not as specified, replace the No. 1 room light switch assembly.
| *a | Component without harness connected
(No. 1 Room Light Switch Assembly) |
Check the illumination.
Apply battery voltage to the connector and check the illumination conditions.
| Battery Connection | Specified Condition |
|---|---|
| Positive → 3(ILL+)
Negative → 2(ILL-) |
Illuminates |
If the result is not as specified, replace the No. 1 room light switch assembly.
| *a | Component without harness connected
(No. 1 Room Light Switch Assembly) |
84170B
2.INSPECT NO. 2 ROOM LIGHT SWITCH ASSEMBLY
Inspect the No. 2 room light switch assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 8(+B) - 5(D) | No. 2 room light switch off | 10 kΩ or higher |
| No. 2 room light switch on | Below 1 Ω |
If the result is not as specified, replace the No. 2 room light switch assembly.
| *a | Component without harness connected
(No. 2 Room Light Switch Assembly) |
Check the illumination.
Apply battery voltage to the connector and check the illumination conditions.
| Battery Connection | Specified Condition |
|---|---|
| Positive → 7(ILL+)
Negative → 6(ILL-) |
Illuminates |
If the result is not as specified, replace the No. 2 room light switch assembly.
| *a | Component without harness connected
(No. 2 Room Light Switch Assembly) |