1.INSPECT CENTER DOOR PANEL SUB-ASSEMBLY
Check that the clearance measurements of areas A to E are within the standard range.
| Area | Measurement Condition | Specified Condition |
|---|---|---|
| A | 2 Coat Application | 5.5 to 8.5 mm (0.216 to 0.335 in.) |
| 4 Coat Application | 5.4 to 8.4 mm (0.213 to 0.331 in.) | |
| B | 2 Coat Application | 1.3 to 4.3mm (0.051 to 0.169 in.) |
| 4 Coat Application | 1.2 to 4.2mm (0.047 to 0.165 in.) | |
| C | 2 Coat Application | 12.1 to 15.1 mm (0.476 to 0.594 in.) |
| 4 Coat Application | 12.1 to 15.1 mm (0.476 to 0.594 in.) | |
| D | 2 Coat Application | 21.6 to 24.6 mm (0.850 to 0.970 in.) |
| 4 Coat Application | 21.6 to 24.6 mm (0.850 to 0.970 in.) | |
| E | 2 Coat Application | 24.4 to 27.4 mm (0.960 to 0.079 in.) |
| 4 Coat Application | 24.3 to 27.3 mm (0.957 to 0.075 in.) |