1.INSPECT AUTOMATIC DOOR REGULATOR MOTOR ASSEMBLY (for LHD)
Check the resistance of the automatic changeover handle position detection switch.
| *1 | Component without harness connected
(Automatic door regulator motor assembly) |
| *a | Manual |
| *b | Automatic |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 9 - 10 | Automatic | 10 kΩ or higher |
| 9 - 10 | Manual | Below 1 Ω |
If the result is not as specified, replace the automatic door regulator motor assembly.
2.INSPECT AUTOMATIC DOOR REGULATOR MOTOR ASSEMBLY (for RHD)
Check the resistance of the automatic changeover handle position detection switch.
| *1 | Component without harness connected
(Automatic door regulator motor assembly) |
| *a | Manual |
| *b | Automatic |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 9 - 10 | Automatic | 10 kΩ or higher |
| 9 - 10 | Manual | Below 1 Ω |
If the result is not as specified, replace the automatic door regulator motor assembly.