Home › Engine / Hybrid System › 1HZ (INTAKE) › TURBOCHARGER
RM2850E _51 Engine / Hybrid System _073298 1HZ INTAKE _0356955 TURBOCHARGER G

1HZ INTAKE  TURBOCHARGER  INSPECTION  


PROCEDURE

Hide 1.INSPECT IMPELLER WHEEL ROTATION

a.
A423233

Grasp the edge of the turbine wheel and turn it. Check that the impeller wheel turns smoothly.

If the impeller wheel does not turn or if it turns with a drag, replace the turbocharger assembly.


Hide 2.INSPECT AXIAL PLAY OF IMPELLER WHEEL

a.
A423234

Insert a dial indicator into the exhaust side, hold the tur-bine wheel edge by hand and check the axial play.

Axial play:

0.13 mm (0.0051 in.) or less


If the axial play is not as specified, replace the turbocharger assembly.


Hide 3.INSPECT RADIAL PLAY OF TURBINE SHAFT

a.
A423235

From the oil outlet hole, insert the dial indicator through the hole in the spacer bearing and set it in the center of the turbine shaft.


b.

Moving the turbine shaft in a radial direction, measure the radial play of the shaft.

Radial play:

0.18 mm (0.0071 in.) or less


If the radial play is not as specified, replace the turbocharger assembly.


Hide 4.INSPECT ACTUATOR OPERATION

a.
A423236

Disconnect the actuator hose.


b.

Using SST (turbocharger pressure gauge), apply approx. 0.92 kg/cm2 (13.1 psi, 90 kpa) of pressure to the actuator and check that the rod moves.

If the rod does not move, replace the turbocharger assembly.

NOTICE:

Never apply more than 1.05 kg/cm2 (14.9 psi, 103 kPa) of pressure to the actuator.