28100
1.INSTALL STARTER ASSEMBLY
Install the starter assembly and wire harness with the 2 bolts.
37 N*m (377 kgf*cm, 27 ft.*lbf)
Connect the terminal 50 connector to the starter assembly.
Attach the starter wire to terminal 30 with the nut.
9.8 N*m (100 kgf*cm, 87 in.*lbf)
2.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL