28300
1.INSPECT STARTER RELAY ASSEMBLY
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
| Tester Connection | Specified Condition |
|---|---|
| 3 - 5 | Below 1 Ω (when battery voltage applied to terminals 1 and 2) |
| 3 - 5 | 10 KΩ or higher |
If the result is not as specified, replace the starter relay.