11301M
1.INSPECT CAMSHAFT POSITION SENSOR
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
| Tester Connection | Specified Condition |
|---|---|
| 1 (G+) - 2 (G-) | 950 to 1,250 Ω at 20°C (68°F) |
If the result is not as specified, replace the camshaft position sensor.