89615
1.INSPECT KNOCK SENSOR
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
| Tester Connection | Specified Condition |
|---|---|
| 1 (Ground) - 2 (Output) | 120 to 280 kΩ at 20 °C (68 °F) |
If the result is not as specified, replace the knock sensor.