89467B
1.INSPECT AIR FUEL RATIO SENSOR
Inspect the A/F heater.
Measure the resistance between terminals 1 (HT) and 2 (+B) of the sensor.
1.8 to 3.4 Ω at 20°C (68°F)
If the result is not as specified, replace the air fuel ratio sensor.
Measure the resistance between terminals 1 (HT) and 4 (AF-) of the sensor.
10 kΩ or higher
If the result is not as specified, replace the air fuel ratio sensor.