16520A
1.INSPECT WATER FILLER CAP SUB-ASSEMBLY
Measure the valve opening pressure.
If there are water stains or foreign matter on rubber packings 1, 2 or 3, clean the parts with water and finger scouring.
Check that rubber packings 1, 2 and 3 are not deformed, cracked or swollen.
Check that rubber packings 3 and 4 are not stuck together.
Apply engine coolant to rubber packings 2 and 3 before using a radiator cap tester.
When using the cap tester, tilt it more than 30 degrees.
Pump the cap tester several times, and check the maximum pressure *1.
1 pump per second
*1: Even if the cap cannot maintain the maximum pressure, it is not a defect.
| Item | Specified Condition |
|---|---|
| Standard value (for brand new cap) | 93 to 123 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi) |
| Minimum standard value (after using cap) | 78.5 kPa (0.8 kgf/cm2, 11.4 psi) |
If the maximum pressure is less than the minimum standard value, replace the water filler cap sub-assembly.