Home › Engine / Hybrid System › 2TR-FE (CHARGING) › GENERATOR (for 80A Type)
RM2850E _51 Engine / Hybrid System _073308 2TR-FE CHARGING _0357055 GENERATOR(for 80A Type) G

2TR-FE CHARGING  GENERATOR(for 80A Type)  INSPECTION  


PROCEDURE

Hide 27370 1.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

a.
A128079E23
0.627,0.709 0.823,0.866 0.197,0.157 10 *a

Using a vernier caliper, measure the brush length.

Standard Exposed Length:

9.5 to 11.5 mm (0.374 to 0.453 in.)


Minimum Exposed Length:

4.5 mm (0.177 in.)


Text in Illustration
*a Length

If the brush length is less than the minimum, replace the generator brush holder assembly.


Hide 27330 2.INSPECT GENERATOR ROTOR ASSEMBLY

a.
A298011

Check that the generator rotor bearing is not rough or worn and that it rotates smoothly.

If necessary, replace the generator rotor assembly.


b.

Check the generator rotor assembly for an open circuit.

i.
A153720E01
2.387,0.551 2.572,0.723 0.186,0.172 10 *a 1.773,1.028 2.372,0.649 2.372,0.649 1.904,1.091 false

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 1.9 to 2.3 Ω


Text in Illustration
*a Slip Ring

If the result is not as specified, replace the generator rotor assembly.



c.

Check the generator rotor assembly for a short to ground.

i.
A153814E04
2.479,0.979 2.354,0.979 2.354,0.979 2.042,1.344 true 2.052,0.198 1.927,0.198 1.927,0.198 1.25,1.021 true 2.51,0.885 2.688,1.052 0.177,0.167 10 false *a 2.063,0.104 2.24,0.271 0.177,0.167 10 false *b

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Rotor core Always 10 kΩ or higher


Text in Illustration
*a Slip Ring
*b Rotor Core

NOTICE:

Perform the check on the fan portion of the rotor core that has not been coated with insulation paint.


If the result is not as specified, replace the generator rotor assembly.



d.

Check each slip ring.

i.

Check that the slip rings are not rough or scored. If the slip rings are rough or scored, replace the generator rotor assembly.


ii.
A182587E01
0.545,0.548 0.701,0.730 0.156,0.181 10 *a

Using a vernier caliper, measure the slip ring diameter.

Standard Diameter:

14.2 to 14.8 mm (0.559 to 0.583 in.)


Minimum Diameter:

14.0 mm (0.551 in.)


Text in Illustration
*a Diameter

If the diameter is less than the minimum, replace the generator rotor assembly.



Hide 27310B 3.INSPECT GENERATOR DRIVE END FRAME BEARING

a.
A399910

Check that the generator drive end frame bearing is not rough or worn.

If necessary, replace the generator drive end frame bearing.