Home › Engine / Hybrid System › 14B (CHARGING) › CHARGING SYSTEM › 2017.01–2019.08
RM2850E _51 Engine / Hybrid System _073310 14B CHARGING _0357071 CHARGING SYSTEM G

14B CHARGING  CHARGING SYSTEM  ON-VEHICLE INSPECTION  


CAUTION / NOTICE / HINT

CAUTION:

If the battery is weak or if the engine is difficult to start, recharge the battery and perform inspections again before returning the vehicle to the customer.


PROCEDURE

Hide 1.CHECK BATTERY CONDITION

a.

Check the battery for damage and deformation. If severe damage, deformation or leakage is found, replace the battery.


b.

Check the volume of electrolyte in each cell (for maintenance-free batteries).

i.

If the electrolyte volume is below the lower line, add distilled water to each cell or replace the battery.



c.
A001259

Check the volume of electrolyte in each cell (for non-maintenance-free batteries).

i.

If the electrolyte volume is below the lower line, add distilled water to each cell. Then, recharge the battery and check the electrolyte specific gravity.

Standard Electrolyte Specific Gravity:

1.25 to 1.29 at 20°C (68°F)


If the result is not as specified, recharge or replace the battery.



d.

Measure the battery voltage.

i.

Turn the ignition switch off and turn on the headlight for 20 to 30 seconds. This will remove the surface charge from the battery.


ii.

Measure the battery voltage between the positive (+) and negative (-) terminals of the battery.

Standard Voltage:

12.6 to 12.8 V at 20°C (68°F)


If the result is not as specified, recharge or replace the battery.



Hide 2.INSPECT BATTERY TERMINAL AND FUSE

a.

Check that the battery terminals are not loose or corroded.

Torque:

5.4 N*m (55 kgf*cm, 48 in.*lbf)


If the terminals are corroded, clean the terminals.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Below 1 Ω


If the result is not as specified, replace the fuse.


Hide 3.INSPECT DRIVE BELT

a.
A101818

Check the belts for wear, cracks and other signs of damage.

If any defects are found, replace the drive belts as a set.


b.
P003788E05
3.028,2.028 3.411,2.136 0.383,0.108 0.57,1.294 0.719,1.473 0.149,0.179 10 *a 1.271,0.015 1.435,0.204 0.164,0.189 10 *b 2.618,0.015 2.781,0.204 0.163,0.189 10 *c

Check that the belt does not touch the bottom of the pulley groove.

Text in Illustration
*a Clearance
*b CORRECT
*c INCORRECT

If the result is not as specified, replace the drive belts as a set.


c.
A429057E01
0.073,0.063 1.406,0.281 1.333,0.219 10 true Generator Assembly

Check the drive belt deflection by pressing on the belt at the points indicated in the illustration with 98 N (10 kgf, 22.0 lbf) of pressure.

Drive Belt Deflection (Single Belt Type):
Item Specified Condition
New belt 8 to 11 mm (0.31 to 0.43 in.)
Used belt 11 to 16 mm (0.43 to 0.63 in.)


Drive Belt Deflection (Double Belt Type):
Item Specified Condition
New belt 9.5 to 13 mm (0.37 to 0.51 in.)
Used belt 14 to 20 mm (0.55 to 0.79 in.)


If the belt deflection is not as specified, adjust it.


d.
A429058E01
1.583,1.448 1.802,1.646 0.219,0.198 10 false *1 2.729,0.26 2.927,0.458 0.198,0.198 10 false *2 2.917,0.979 3.135,1.177 0.219,0.198 10 false *1

Using belt tension gauge and belt tension gauge cable, check the drive belt tension.

Text in Illustration
*1 Belt Tension Gauge
*2 Belt Tension Gauge Cable

Drive Belt Tension (Single Belt Type):
Item Specified Condition
New belt 421 to 657 N (43 to 67 kgf, 94.6 to 147.7 lbf)
Used belt 245 to 441 N (25 to 45 kgf, 55.1 to 99.1 lbf)


Drive Belt Tension (Double Belt Type):
Item Specified Condition
New belt 275 to 510 N (28 to 52 kgf, 61.8 to 114.7 lbf)
Used belt 196 to 392 N (20 to 40 kgf, 44.1 to 88.1 lbf)


If the belt tension is not as specified, adjust it.

HINT:
·

When checking the belt tension, check that the belt tension gauge tip is on the belt protrusion (single belt type) or belt groove (double belt type).

·

"New belt" refers to a belt which has been used less than 5 minutes on a running engine.

·

"Used belt" refers to a belt which has been used on a running engine for 5 minutes or more.

·

After installing a new belt, run the engine for about 5 minutes and recheck the belt tension.




Hide 4.INSPECT GENERATOR WIRING

a.

Check that the wiring is in good condition.


Hide 5.CHECK FOR ABNORMAL NOISE FROM GENERATOR

a.

Check that the generator does not emit any abnormal noise while the engine is running.


Hide 6.INSPECT CHARGE WARNING LIGHT CIRCUIT

a.

Turn the ignition switch to ON. Check that the charge warning light turns on.


b.

Start the engine and check that the light turns off. If the light does not operate as specified, troubleshoot the charge warning light circuit.


Hide 7.INSPECT CHARGING CIRCUIT WITHOUT LOAD

a.
A428175E01
1.281,0.677 1.594,0.875 0.313,0.198 10 false *a 2.573,2.25 2.885,2.448 0.313,0.198 10 false *1 1.635,2.177 1.948,2.375 0.313,0.198 10 false *b 0.385,2.219 0.698,2.417 0.313,0.198 10 false *2

Connect a voltmeter and an ammeter to the charging circuit as follows.

HINT:

If a battery/generator tester is available, connect the tester to the charging circuit in accordance with the manufacturer's instructions.


i.

Disconnect the wire from terminal B of the generator and connect it to the negative (-) lead of the ammeter.


ii.

Connect the ammeter positive (+) lead to terminal B of the generator.


iii.

Connect the voltmeter positive (+) lead to terminal B of the generator.


iv.

Ground the voltmeter negative (-) lead.

Text in Illustration
*1 Generator Assembly
*2 Battery
*a Ammeter
*b Voltmeter



b.

Check the charging circuit.

i.

Keep the engine speed at 2000 rpm and check the reading on the ammeter and voltmeter.

Standard Current:

10 A or higher


Standard Voltage:

12.9 to 14.9 V


If the result is not as specified, replace the generator.

HINT:

If the battery is not fully charged, the ammeter reading will sometimes be more than the standard current.




Hide 8.INSPECT CHARGING CIRCUIT WITH LOAD

a.

With the engine running at 2000 rpm, turn on the high beam headlights and turn the heater blower switch to the HI position.


b.

Check the reading on the ammeter.

Standard Current:

30 A or higher


If the ammeter reading is less than the standard current, replace the generator.

HINT:

If the battery is fully charged, the ammeter reading will sometimes be less than the standard current.

In this case, operate the wiper motor and the window defogger to increase the load and then check the charging circuit again.