Hide 27700A 1.INSPECT IC REGULATOR

a.
A422147

Using an ohmmeter, check the continuity between terminals F and B.

Standard:

When the positive and negative poles between terminals F and B are exchanged, there is continuity in one way but no continuity in another way.

If the continuity is not as specified, replace the IC regulator.


b.
A422148

Using an ohmmeter, check the continuity between terminals F and E.

Standard:

When the positive and negative poles between terminals F and B are exchanged, there is continuity in one way but no continuity in another way.

If the continuity is not as specified, replace the IC regulator.


Hide 27330 2.INSPECT ROTOR FOR OPEN CIRCUIT

a.
A422149

Using an ohmmeter, check that there is continuity between the slip rings.

Standard resistance:

2.7 - 3.1 Ω at 20°C (68°F)


If there is no continuity, replace the rotor.


Hide 27330 3.INSPECT ROTOR FOR GROUND

a.
A422150

Using an ohmmeter, check that there is no continuity between the slip ring and rotor.

If there is continuity, replace the rotor.


Hide 4.INSPECT SLIP RINGS

a.
A422151

Check that the slip rings are not rough or scored.

If rough or scored, replace the rotor.


b.

Using vernier calipers, measure the slip ring diameter.

Standard diameter:

14.2 - 14.4 mm (0.559 - 0.567 in.)


Minimum diameter:

12.8 mm (0.504 in.)


If the diameter is less than minimum, replace the rotor.


Hide 27020 5.INSPECT STATOR FOR OPEN CIRCUIT

a.
A422152

Using an ohmmeter, check that there is continuity between the coil leads.

If there is no continuity, replace the drive end frame.


Hide 27020 6.INSPECT STATOR FOR GROUND

a.
A422153

Using an ohmmeter, check that there is no continuity between the coil lead and drive end frame.

If there is continuity, replace the drive end frame.


Hide 7.INSPECT EXPOSED BRUSH LENGTH

a.
A422154

Using a scale or vernier caliper, measure the exposed brush length.

Standard exposed length:

9.5 - 11.5 mm (0.374 - 0.453 in.)


Minimum exposed length:

1.5 mm ( 0.059 in.)


If the exposed length is less than minimum, replace the brush holder.


Hide 27357 8.INSPECT POSITIVE RECTIFIER

a.
A422155

Using an ohmmeter, connect one tester probe to the positive (+) terminal and the other to each rectifier terminal.


b.

Reverse the polarity of the tester probes and repeat step (a).


c.

Check that one shows continuity and the other shows no continuity.

If continuity is not as specified, replace the rectifier holder.


Hide 27357 9.INSPECT NEGATIVE RECTIFIER

a.
A422156

Using an ohmmeter, connect one tester probe to each negative (-) terminal and the other to each rectifier terminal.


b.

Reverse the polarity of the tester probes and repeat step (a).


c.

Check that one shows continuity and the other shows no continuity.

If continuity is not as specified, replace the rectifier holder.


Hide 10.INSPECT FRONT AND REAR BEARING

a.

Check that the bearing is not rough or worn.


b.

If necessary, replace the bearing.