Home › Engine / Hybrid System › N04C-UH (CHARGING) › CHARGING SYSTEM
RM2850E _51 Engine / Hybrid System _073313 N04C-UH CHARGING _0357077 CHARGING SYSTEM G

N04C-UH CHARGING  CHARGING SYSTEM  ON-VEHICLE INSPECTION  


CAUTION / NOTICE / HINT

CAUTION:

If the battery is weak or if the engine is difficult to start, recharge the battery and perform inspections again before returning the vehicle to the customer.


PROCEDURE

Hide 1.CHECK BATTERY CONDITION

a.

Check the battery for damage and deformation. If severe damage, deformation or leakage is found, replace the battery.


b.

Check the volume of electrolyte in each cell (for maintenance-free batteries).

i.

If the electrolyte volume is below the lower line, add distilled water to each cell or replace the battery.



c.
A001259

Check the volume of electrolyte in each cell (for non-maintenance-free batteries).

i.

If the electrolyte volume is below the lower line, add distilled water to each cell. Then, recharge the battery and check the electrolyte specific gravity.

Standard Electrolyte Specific Gravity:

1.25 to 1.29 at 20°C (68°F)


If the result is not as specified, recharge or replace the battery.



d.

Measure the battery voltage.

i.

Turn the ignition switch off and turn on the headlight for 20 to 30 seconds. This will remove the surface charge from the battery.


ii.

Measure the battery voltage between the positive (+) and negative (-) terminals of the battery.

Standard Voltage:

12.6 to 12.8 V at 20°C (68°F)


If the result is not as specified, recharge or replace the battery.



Hide 2.INSPECT BATTERY TERMINAL AND FUSE

a.

Check that the battery terminals are not loose or corroded.

Torque:

3.9 N*m (40 kgf*cm, 35 ft.*lbf)


If the terminals are corroded, clean the terminals.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Below 1 Ω


If the result is not as specified, replace the fuse.


Hide 3.INSPECT DRIVE BELT

a.
A101818

Check the belts for wear, cracks and other signs of damage.

If any defects are found, replace the drive belts as a set.


b.
P003788E08
0.573,1.292 0.719,1.469 0.146,0.177 10 false *a 1.271,0.063 1.438,0.25 0.167,0.188 10 false *b 2.615,0.073 2.781,0.26 0.167,0.188 10 false *c

Check that the belt does not touch the bottom of the pulley groove.

Text in Illustration

If the result is not as specified, replace the drive belts as a set.

*a Clearance
*b CORRECT
*c INCORRECT


Hide 4.INSTALL GENERATOR WIRING

a.

Check that the wiring is in good condition.


Hide 5.CHECK FOR ABNORMAL NOISE FROM GENERATOR

a.

Check that the generator does not emit any abnormal noise while the engine is running.


Hide 6.INSPECT CHARGE WARNING LIGHT CIRCUIT

a.

Turn the ignition switch to ON. Check that the charge warning light turns on.


b.

Start the engine and check that the light turns off. If the light does not operate as specified, troubleshoot the charge warning light circuit.


Hide 7.INSPECT CHARGING CIRCUIT WITHOUT LOAD

a.
A118255E07
1.292,0.688 1.448,0.854 0.156,0.167 10 false *a 1.646,2.104 1.813,2.25 0.167,0.146 10 false *b 2.552,2.26 2.729,2.427 0.177,0.167 10 false *1 0.406,2.188 0.563,2.365 0.156,0.177 10 false *2

Connect a voltmeter and an ammeter to the charging circuit as follows.

HINT:

If a battery/generator tester is available, connect the tester to the charging circuit in accordance with the manufacturer's instructions.


i.

Disconnect the wire from terminal B of the generator and connect it to the negative (-) lead of the ammeter.


ii.

Connect the ammeter positive (+) lead to terminal B of the generator.


iii.

Connect the voltmeter positive (+) lead to terminal B of the generator.


iv.

Ground the voltmeter negative (-) lead.

Text in Illustration
*1 Generator Assembly
*2 Battery
*a Ammeter
*b Voltmeter



b.

Check the charging circuit.

i.

Keep the engine speed at 2000 rpm and check the reading on the ammeter and voltmeter.

Standard Current:

10 A or higher


Standard Voltage:

13.2 to 14.8 V


If the result is not as specified, replace the generator.

HINT:

If the battery is not fully charged, the ammeter reading will sometimes be more than the standard current.




Hide 8.INSPECT CHARGING CIRCUIT WITH LOAD

a.

With the engine running at 2000 rpm, turn on the high beam headlights and turn the heater blower switch to the HI position.


b.

Check the reading on the ammeter.

Standard Current:

30 A or higher


If the ammeter reading is less than the standard current, replace the generator.

HINT:

If the battery is fully charged, the ammeter reading will sometimes be less than the standard current.

In this case, operate the wiper motor and the window defogger to increase the load and then check the charging circuit again.