Home › General › SPECIFICATIONS › N04C-VQ COOLING
RM2850E _V1 General _073185 SPECIFICATIONS _0364996 N04C-VQ COOLING F

SPECIFICATIONS  N04C-VQ COOLING  SERVICE DATA  


Thermostat Valve opening temperature 80 to 84°C (176 to 183°F)
Valve lift 10 mm (0.394 in.) or more at 95°C (203°F)
Radiator cap sub-assembly Standard value (for brand new cap) 93 to 123 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)
Minimum standard value (for used cap) 78 kPa (0.8 kgf/cm2, 11.4 psi)