*: The output voltage changes depending on the voltage applied to the terminals.

Injector assembly Standard resistance
1 - 2
0.85 to 1.05 Ω at 20 °C (68 °F)
Suction control valve (Injection or supply pump assembly) Standard resistance
1 - 2
1.9 to 2.3 Ω at 20 °C (68 °F)
Fuel temperature sensor (Injection or supply pump assembly) Standard resistance
1 - 2
2.21 to 2.69 kΩ at 20 °C (68 °F)
0.287 to 0.349 kΩ at 80 °C (176 °F)
Fuel pressure sensor (Common rail assembly) Standard resistance
2 - 3
5 - 4
16.4 kΩ or less at 20 °C (68 °F)
Standard resistance
1 - 2
6 - 5
3 kΩ or less at 20 °C (68 °F)
Level warning switch Standard resistance
Switch ON
1 - 2
Below 1 Ω
Standard resistance
Switch OFF
1 - 2
10 kΩ or higher
Clogging switch Standard resistance
1 - 2
Below 1 Ω at 20 °C (68 °F)
Fuel sender gauge assembly Standard voltage
2 - 3
4.255 to 4.065 V* at F (Upper End)