Home › General › SPECIFICATIONS › N04C-VL INTAKE
RM2850E _V1 General _073185 SPECIFICATIONS _0366748 N04C-VL INTAKE F

SPECIFICATIONS  N04C-VL INTAKE  SERVICE DATA  


Turbo pressure sensor Standard pressure 40 to 70 kPa (0.41 to 0.71 kgf/cm2, 5.8 to 10.2 psi)
Standard voltage 3 - 1 4.5 to 5.5 V
Applied Pressure:
93.0 kPa (0.95 kgf/cm2, 13.5 psi)
E55-5 (PIM) - E55-14 (E2) 0.25 to 0.40 V
Applied Pressure:
150 kPa (1.53 kgf/cm2, 21.8 psi)
1.0 to 1.4 V
Turbine shaft Axial play Maximum 0.09 mm (0.00354 in.)
Radial play Maximum 0.17 mm (0.0067 in.)