RM2850E
_V1
General
_073185
SPECIFICATIONS
_0367623
14B STARTING
F
SPECIFICATIONS 14B STARTING SERVICE DATA
PRE-HEATING SYSTEM
| Light lighting time
|
at 20°C (68°F)
|
2.4 seconds
|
| at 0°C (32°F)
|
Approx. 5 seconds
|
STARTER
| Rated voltage and output power
|
12 V 2.5 kW
24 V 4.5 kW
|
| No-load characteristics
|
Current (2.5 kW)
|
180 A or less at 11.0 V
|
| Current (4.5 kW)
|
90 A or less at 23.0 V
|
| rpm
|
3,500 rpm or more
|
| Brush length
|
Standard length
|
20.5 - 21.0 mm (0.807 - 0.827 in.)
|
| Minimum length
|
13.5 mm (0.531 in.)
|
| Spring installed load
|
32 - 38 N (3.3 - 3.9 kgf, 7.3 - 8.5 lbf)
|
| Commutator
|
Standard diameter
|
36 mm (1.42 in.)
|
| Minimum diameter
|
35 mm (1.38 in.)
|
| Standard undercut depth
|
0.7 - 0.9 mm (0.028 - 0.035 in.)
|
| Minimum undercut depth
|
0.2 mm (0.008 in.)
|
| Maximum runout
|
0.05 mm (0.0020 in.)
|
| Magnetic switch
|
Maximum wear
|
1.6 mm (0.063 in.)
|
IGNITION SWITCH
| Tester Connection
|
Switch Condition
|
Specified Condition
|
| Between all terminals
|
LOCK
|
10 kΩ or higher
|
| 4 (ACC) - 6 (AM1)
|
ACC
|
Below 1 Ω
|
| 4 (ACC) - 6 (AM1)
|
ON
|
Below 1 Ω
|
| 5 (IG1) - 6 (AM1)
|
| 11 (IG2) - 12 (AM2)
|
| 5 (IG1) - 6 (AM1)
|
START
|
Below 1 Ω
|
| 3 (ST1) - 6 (AM1)
|
| 11 (IG2) - 12 (AM2)
|
| 9 (ST2) - 12 (AM2)
|