Home › General › SPECIFICATIONS › 1BZ-FPE ENGINE CONTROL
RM2850E _V1 General _073185 SPECIFICATIONS _0368667 1BZ-FPE ENGINE CONTROL F

SPECIFICATIONS  1BZ-FPE ENGINE CONTROL  SERVICE DATA  


High-tension cord Maximum resistance 25 kW per cord
Ignition coil Primary coil resistance Cold 0.36 to 0.55 W
Hot 0.45 to 0.65 W
Secondary coil resistance Cold 9.0 to 15.4 kW
Hot 11.4 to 18.1 kW
Signal generator (pickup coil) Primary coil resistance Cold 135 to 220 W
Hot 175 to 255 W
Distributor Air gap 0.2 to 0.4 mm (0.008 to 0.016 in.)
Igniter Standard resistance I15-5 - I16-2 Below 1 W
Spark plug Recommended spark plug DENSO made DK16R-B5
Maximum electrode gap for used spark plug 0.70 mm (0.0276 in.)
Electrode gap for new spark plug 0.4 to 0.5 mm (0.016 to 0.020 in.)
Heated oxygen sensor Standard resistance 1 (HT) - 2 (+B) 11 to 16 kΩ at 20°C (68°F)
1 (HT) - 4 (E1) 10 kΩ or higher
IG 1 No. 3 relay Standard resistance 3 - 5 Battery voltage not applied 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω
IG 1 No. 4 relay Standard resistance 3 - 5 Battery voltage not applied 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω
ENG MAIN/LPG relay Standard resistance 3 - 5 Battery voltage not applied 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω
ENG STOP relay Standard resistance 3 - 4 Battery voltage not applied Below 1 Ω
Battery voltage applied to terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage not applied 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω
No. 2 Integration relay
(EDU relay)
Standard resistance 2E-1 - 2C-4 Battery voltage not applied to terminals 2C-2 and 2C-3 10 kΩ or higher
Battery voltage applied to terminals 2C-2 and 2C-3 Below 1 Ω
No. 2 Integration relay
(IG2 relay)
Standard resistance 2E-1 - 2C-8 Battery voltage not applied to terminals 2C-6 and 2C-7 10 kΩ or higher
Battery voltage applied to terminals 2C-6 and 2C-7 Below 1 Ω
No. 2 Integration relay
(EFI relay)
Standard resistance 2E-1 - 2D-4 Battery voltage not applied to terminals 2D-2 and 2D-3 10 kΩ or higher
Battery voltage applied to terminals 2D-2 and 2D-3 Below 1 Ω
No. 2 Integration relay
(A/F HTR relay)
Standard resistance 2E-1 - 2D-8 Battery voltage not applied to terminals 2D-6 and 2D-7 10 kΩ or higher
Battery voltage applied to terminals 2D-2 and 2D-3 Below 1 Ω