RM2850E
_V1
General
_073185
SPECIFICATIONS
_0367621
14B COOLING
F
SPECIFICATIONS 14B COOLING TORQUE SPECIFICATIONS
| Part tightened
|
N*m
|
kgf*cm
|
ft.*lbf
|
| Coolant drain plug x Union on cylinder block
|
24.5
|
250
|
18
|
| Water pump x cylinder block
|
25
|
255
|
18
|
| Radiator pipe x Timing gear case
|
21
|
214
|
15
|
| Fan x Fluid coupling (w/ Fluid coupling)
|
6.5
|
66
|
57 in.*lbf
|
| Fluid coupling x Water pump pulley (w/ Fluid coupling)
|
18.5
|
189
|
14
|
| Fan x Water pump pulley (w/o Fluid coupling)
|
18.5
|
189
|
14
|
| Alternator x Alternator bracket
|
37.5
|
382
|
28
|
| Alternator x Alternator adjusting bar
|
18.5
|
189
|
14
|
| Water outlet x Water outlet housing
|
18.5
|
189
|
14
|
| Support x Tank on radiator
|
12.7
|
130
|
9
|