FAIL-SAFE CHART
The door control relay assembly operates in fail safe mode if an abnormal condition such as those listed below has been detected.
| Item | Abnormality Detection Condition | Fail-safe Operation | Return Condition |
|---|---|---|---|
| Center door position malfunction | Abnormal door position isdetected | While abnormality being detected
·
Center door motor is stopped and power is supplied to the magnetic clutch for 3 seconds. ·
Buzzer sounds for 3 seconds from when power supply to magnetic clutch started.
After abnormality detected
·
Intermittent clutch control continues until specified period of time elapses. ·
Auto control cannot beactivated.
|
Center door fully-closed state is detected. |
| Pulse Sensor Malfunction | When the center door is in automatic opening or closing operation, abnormality in pulse sensor is detected. | While abnormality being detected
·
Center door motor is stopped and power is supplied to the magnetic clutch for 3 seconds. ·
Buzzer sounds for 3 seconds from when power supply to magnetic clutch started.
After abnormality detected
Intermittent clutch control is performed.
|
Intermittent clutch control period has ended and center door fully closed state is detected. |
| Continuous power supply to driving motor in the same direction | When power is supplied in the same direction to the center door motor for more than 30 seconds. | While abnormality being detected
·
Center door motor is stopped and power is supplied to the magnetic clutch for 3 seconds. ·
Buzzer sounds for 3 seconds from when power supply to magnetic clutch started.
After abnormality detected
Strong brake control is performed.
|
When power supply in the same direction to the center door motoris turned off. |
| Continuous power supply to the clutch | Continuous power supply time to the magnetic clutch has elapsed 2 minutes.
|
While abnormality being detected
·
Center door motor is stopped and power is supplied to the magnetic clutch for 3 seconds. ·
Buzzer sounds for 3 seconds from when power supply to magnetic clutch started.
After abnormality detected
Strong brake control is performed.
|
Continuous power supply to the magnetic clutch is turned off. |
| Latch malfunction | If center door fully-closed state is not detected when closing operation is completed. | Buzzer sounds for 15 seconds. | Returns immediately. |
| Full open latch switch malfunction | When the door has been obstructed several times in series within the range where full-openlatch can be held engaged. | While abnormality being detected
Buzzer sounds for 3 seconds. After abnormality detected
When the door has been obstructed within the range where full-open latch can be held engaged before return conditions are met, the buzzer sounds for 3 seconds.
|
While the center door is in automatic opening operation, the full-open switch is turned from off to on within the range where thefull-open latch can be held engaged. |
| Release motor switch malfunction | While the release motor is in operation, full-switch abnormality or initial switch abnormality is detected. | While abnormality being detected
·
Center door motor is stopped and power is supplied to the magnetic clutch for 3 seconds. ·
Buzzer sounds for 3 seconds from when power supply to magnetic clutch started.
After abnormality detected
Strong brake control is performed.
|
Resets the ECU power source |