Home › Engine / Hybrid System › N04C-WA (EMISSION CONTROL) › UREA SELECTIVE CATALYTIC REDUCTION SYSTEM › from 2019.08
RM2850E _51 Engine / Hybrid System _082614 N04C-WA EMISSION CONTROL _0400651 UREA SELECTIVE CATALYTIC REDUCTION SYSTEM U

N04C-WA EMISSION CONTROL  UREA SELECTIVE CATALYTIC REDUCTION SYSTEM  FAIL-SAFE CHART  


FAIL-SAFE CHART


If any of the following DTCs are stored, the DCU (emission control ECU assembly) enters fail-safe mode to allow the vehicle to be driven temporarily.

DTC No. Detection Item Fail-safe Operation Fail-safe Deactivation Condition
P007162 Ambient Air Temperature Sensor Circuit "A" Range/Performance Signal Compare Failure
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P007211 Ambient Air Temperature Sensor Circuit "A" Low Circuit Short to Ground
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P007315 Ambient Air Temperature Sensor Circuit "A" High Circuit Short to Battery or Open
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P0562A2 System Voltage Low System Voltage Low
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P0563A3 System Voltage High System Voltage High
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P060541 Internal Control Module Read Only Memory (ROM) Error General Checksum Failure
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P0642A2 Sensor Reference Voltage "A" Circuit Low System Voltage Low
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P0643A3 Sensor Reference Voltage "A" Circuit High System Voltage High
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P0652A2 Sensor Reference Voltage "B" Circuit Low System Voltage Low
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P0653A3 Sensor Reference Voltage "B" Circuit High System Voltage High
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P202E71 Reductant Injection Valve Circuit Range/Performance Bank 1 Unit 1 Actuator Stuck
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P203B64 Reductant Level Sensor "A" Circuit Range/Performance Signal Plausibility Failure
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P203C11 Reductant Level Sensor "A" Circuit Low Circuit Short to Ground
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P203D15 Reductant Level Sensor "A" Circuit High Circuit Short to Battery or Open
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P204362 Reductant Temperature Sensor "A" Circuit Range/Performance Signal Compare Failure
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P204414 Reductant Temperature Sensor "A" Circuit Low Circuit Short to Ground or Open
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P204512 Reductant Temperature Sensor "A" Circuit High Circuit Short to Battery
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P204811 Reductant Injection Valve Circuit Low Bank 1 Unit 1 Circuit Short to Ground
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P204915 Reductant Injection Valve Circuit High Bank 1 Unit 1 Circuit Short to Battery or Open
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P204B64 Reductant Pressure Sensor Circuit Range/Performance Signal Plausibility Failure
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P204C11 Reductant Pressure Sensor Circuit Low Circuit Short to Ground
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P204D15 Reductant Pressure Sensor Circuit High Circuit Short to Battery or Open
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P205B62 Reductant Tank Temperature Sensor "A" Circuit Range/Performance Signal Compare Failure
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P205C11 Reductant Tank Temperature Sensor "A" Circuit Low Circuit Short to Ground
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P205D15 Reductant Tank Temperature Sensor "A" Circuit High Circuit Short to Battery or Open
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P206A01 Reductant Quality Sensor Circuit General Electrical Failure
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P206B64 Reductant Quality Sensor Circuit Range/Performance Signal Plausibility Failure
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P206C11 Reductant Quality Sensor Circuit Low Circuit Short to Ground
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P206D15 Reductant Quality Sensor Circuit High Circuit Short to Battery or Open
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P208B77 Reductant Pump "A" Control Performance/Stuck Off Commanded Position Not Reachable
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P208C11 Reductant Pump "A" Control Circuit Low Circuit Short to Ground
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P208D15 Reductant Pump "A" Control Circuit High Circuit Short to Battery or Open
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P20B914 Reductant Heater "A" Control Circuit/Open Circuit Short to Ground or Open
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P20BC12 Reductant Heater "A" Control Circuit High Circuit Short to Battery
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P20BD14 Reductant Heater "B" Control Circuit/Open Circuit Short to Ground or Open
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P20BE92 Reductant Heater "B" Control Circuit Performance Performance or Incorrect Operation
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P20C012 Reductant Heater "B" Control Circuit High Circuit Short to Battery
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P20E865 Reductant Pressure Too Low Signal Has Too Few Transitions / Events
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P20E985 Reductant Pressure Too High Signal Above Allowable Range
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P20F49C Reductant Consumption Too Low Low/Insufficient Flow
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
P248111 Exhaust Gas Temperature Sensor Circuit Low Bank 1 Sensor 5 Circuit Short to Ground
·

Exhaust gas temperature (SCR inlet) is fixed at a specified value.

·

The engine power is limited.


Pass condition detected
P248215 Exhaust Gas Temperature Sensor Circuit High Bank 1 Sensor 5 Circuit Short to Battery or Open
·

Exhaust gas temperature (SCR inlet) is fixed at a specified value.

·

The engine power is limited.


Pass condition detected
U010031 Lost Communication with ECM/PCM "A" No Signal
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected
U02A231 Lost Communication with Reductant Quality Module No Signal
·

Urea SCR system is stopped.

·

The engine power is limited.


Pass condition detected