FAIL-SAFE CHART
If any of the following DTCs are stored, the DCU (emission control ECU assembly) enters fail-safe mode to allow the vehicle to be driven temporarily.
| DTC No. | Detection Item | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|---|
| P007162 | Ambient Air Temperature Sensor Circuit "A" Range/Performance Signal Compare Failure | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P007211 | Ambient Air Temperature Sensor Circuit "A" Low Circuit Short to Ground | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P007315 | Ambient Air Temperature Sensor Circuit "A" High Circuit Short to Battery or Open | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P0562A2 | System Voltage Low System Voltage Low | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P0563A3 | System Voltage High System Voltage High | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P060541 | Internal Control Module Read Only Memory (ROM) Error General Checksum Failure | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P0642A2 | Sensor Reference Voltage "A" Circuit Low System Voltage Low | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P0643A3 | Sensor Reference Voltage "A" Circuit High System Voltage High | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P0652A2 | Sensor Reference Voltage "B" Circuit Low System Voltage Low | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P0653A3 | Sensor Reference Voltage "B" Circuit High System Voltage High | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P202E71 | Reductant Injection Valve Circuit Range/Performance Bank 1 Unit 1 Actuator Stuck | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P203B64 | Reductant Level Sensor "A" Circuit Range/Performance Signal Plausibility Failure | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P203C11 | Reductant Level Sensor "A" Circuit Low Circuit Short to Ground | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P203D15 | Reductant Level Sensor "A" Circuit High Circuit Short to Battery or Open | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P204362 | Reductant Temperature Sensor "A" Circuit Range/Performance Signal Compare Failure | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P204414 | Reductant Temperature Sensor "A" Circuit Low Circuit Short to Ground or Open | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P204512 | Reductant Temperature Sensor "A" Circuit High Circuit Short to Battery | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P204811 | Reductant Injection Valve Circuit Low Bank 1 Unit 1 Circuit Short to Ground | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P204915 | Reductant Injection Valve Circuit High Bank 1 Unit 1 Circuit Short to Battery or Open | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P204B64 | Reductant Pressure Sensor Circuit Range/Performance Signal Plausibility Failure | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P204C11 | Reductant Pressure Sensor Circuit Low Circuit Short to Ground | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P204D15 | Reductant Pressure Sensor Circuit High Circuit Short to Battery or Open | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P205B62 | Reductant Tank Temperature Sensor "A" Circuit Range/Performance Signal Compare Failure | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P205C11 | Reductant Tank Temperature Sensor "A" Circuit Low Circuit Short to Ground | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P205D15 | Reductant Tank Temperature Sensor "A" Circuit High Circuit Short to Battery or Open | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P206A01 | Reductant Quality Sensor Circuit General Electrical Failure | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P206B64 | Reductant Quality Sensor Circuit Range/Performance Signal Plausibility Failure | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P206C11 | Reductant Quality Sensor Circuit Low Circuit Short to Ground | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P206D15 | Reductant Quality Sensor Circuit High Circuit Short to Battery or Open | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P208B77 | Reductant Pump "A" Control Performance/Stuck Off Commanded Position Not Reachable | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P208C11 | Reductant Pump "A" Control Circuit Low Circuit Short to Ground | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P208D15 | Reductant Pump "A" Control Circuit High Circuit Short to Battery or Open | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P20B914 | Reductant Heater "A" Control Circuit/Open Circuit Short to Ground or Open | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P20BC12 | Reductant Heater "A" Control Circuit High Circuit Short to Battery | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P20BD14 | Reductant Heater "B" Control Circuit/Open Circuit Short to Ground or Open | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P20BE92 | Reductant Heater "B" Control Circuit Performance Performance or Incorrect Operation | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P20C012 | Reductant Heater "B" Control Circuit High Circuit Short to Battery | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P20E865 | Reductant Pressure Too Low Signal Has Too Few Transitions / Events | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P20E985 | Reductant Pressure Too High Signal Above Allowable Range | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P20F49C | Reductant Consumption Too Low Low/Insufficient Flow | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| P248111 | Exhaust Gas Temperature Sensor Circuit Low Bank 1 Sensor 5 Circuit Short to Ground | ·
Exhaust gas temperature (SCR inlet) is fixed at a specified value. ·
The engine power is limited. |
Pass condition detected |
| P248215 | Exhaust Gas Temperature Sensor Circuit High Bank 1 Sensor 5 Circuit Short to Battery or Open | ·
Exhaust gas temperature (SCR inlet) is fixed at a specified value. ·
The engine power is limited. |
Pass condition detected |
| U010031 | Lost Communication with ECM/PCM "A" No Signal | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |
| U02A231 | Lost Communication with Reductant Quality Module No Signal | ·
Urea SCR system is stopped. ·
The engine power is limited. |
Pass condition detected |