DATA LIST
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Start the engine.
Warm up the engine.
Turn the GTS on.
Enter the following menus: Powertrain / Urea Selective Catalytic Reduction / Data List.
Check the values by referring to the table below.
Normal Condition: If no idling conditions are specified, the shift lever should be in N, and the A/C switch and all accessory switches are OFF.
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
LIST OF DATA LIST
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Vehicle Speed | Vehicle speed | Min.: 0 km/h, Max.: 255.99 km/h | Actual vehicle speed | The vehicle speed is detected using the wheel speed sensors. |
| Engine Speed | Engine speed | Min.: 0 rpm, Max.: 8191 rpm | Actual engine speed | The engine speed is the crankshaft position sensor output value. |
| Accelerator Position | Accelerator pedal position | Min.: 0%, Max.: 102% | 0%: Accelerator pedal fully released | Outputs the accelerator position. |
| Engine Exhaust Flow Rate | Exhaust flow rate | Min.: 0 kg/h, Max.: 13107 kg/h | - | Outputs the engine exhaust flow rate. |
| Key Switch | Ignition switch status | ON or OFF | ON: Ignition switch ON | Outputs the ignition switch status. |
| Auxiliary Battery Voltage | Battery voltage | Min.: 0 V, Max.: 51 V | 11 to 14 V: Ignition switch ON | If 11 V or less, characteristics of some electrical components may change. |
| Sensor Power Supply Voltage 1 | Power source of pressure sensor (urea pump) | Min.: 0 V, Max.: 5.1 V | 4.5 to 5.1 V: Ignition switch ON | Outputs the power supply voltage for the pressure sensor (urea pump). |
| Sensor Power Supply Voltage 2 | Power source of level sensor (urea pump) | Min.: 0 V, Max.: 5.1 V | 4.5 to 5.1 V: Ignition switch ON | Outputs the power supply voltage for the level sensor (urea pump). |
| Ambient Temperature | Ambient temperature | Min.: -40°C, Max.: 215°C | Equivalent to ambient temperature | Outputs the ambient temperature. |
| Ambient Temperature Sensor Voltage | Ambient temperature sensor (cooler thermistor) output voltage | Min.: 0 V, Max.: 5.1 V | - | Outputs the voltage of the ambient temperature sensor (cooler thermistor). |
| SCR Exhaust Temperature | Exhaust gas temperature of SCR inlet | Min.: -273°C, Max.: 1774.96°C | - | Outputs the exhaust temperature of the SCR inlet. |
| SCR Exhaust Temperature Sensor Voltage | Exhaust gas temperature of SCR inlet output voltage | Min.: 0 V, Max.: 5.1 V | - | Outputs the voltage of the SCR inlet exhaust temperature sensor. |
| DPF Exhaust Temperature | Exhaust gas temperature of DPF outlet | Min.: -273°C, Max.: 1774.96°C | - | Outputs the exhaust temperature of the DPF outlet. |
| System Status | Urea SCR system control mode status | OFF / Idle / Pressure Rising / Pressure Keep / After Run / Service Mode Idle / Standby / Service Mode Stop / Start Up Test / Service Pressure Rising / Service Pressure Keep / Service Injection / Leak Test / Service Pump Test / Service Pump Active / Service Pump Stop | - | Outputs the urea SCR system status. |
| Target Reductant Injection Volume | Target urea injection volume | Min.: 0 g/h, Max.: 65535 g/h | - | Outputs the target urea injection assembly volume. |
| Reductant Temperature | Urea solution temperature of urea solution quality sensor (urea sensor assembly) | Min.: -40°C, Max.: 215°C | - | Outputs the urea solution temperature of the urea solution quality sensor (urea sensor assembly). |
| Reductant Level | Urea solution level | Min.: 0 L, Max.: 13.107 L | - | Outputs the urea solution level. |
| Reductant Density | Urea solution density | Min.: 0%, Max.: 63.75% | 28.4 to 35.2% | Outputs the urea solution density. |
| Reductant Pipe Heater Duty | Urea pipe heater control duty ratio | Min.: 0%, Max.: 255% | - | Outputs the duty ratio of the urea pipe heater. |
| Reductant Quality Information | Urea solution quality information status | Reductant Density High / Reductant Density Low / Other than Reductant / Normal / Empty / Unknown | Normal | Outputs the urea solution quality information. |
| Reductant Tank Heater Duty | Urea tank heater control duty ratio | Min.: 0%, Max.: 255% | - | Outputs the duty ratio of the urea tank heater. |
| Reductant Tank Temperature | Urea solution temperature of urea pump | Min.: -40°C, Max.: 215°C | - | Outputs the urea solution temperature of the urea tank. |
| Reductant Tank Temperature Sensor Voltage | Temperature sensor (urea pump) output voltage | Min.: 0 V, Max.: 5.1 V | - | Outputs the voltage of the temperature sensor (urea pump). |
| Reductant Tank Level Sensor Voltage | Level sensor (urea pump) output voltage | Min.: 0 V, Max.: 5.1 V | - | Outputs the voltage of the level sensor (urea pump). |
| Reductant Pump Pressure | Urea pump pressure | Min.: -1 bar, Max.: 24.5 bar | 4.5 to 5.5 bar:
Engine running |
Outputs the pressure of the urea pump. |
| Reductant Pump Pressure Sensor Voltage | Pressure sensor (urea pump) output voltage | Min.: 0 V, Max.: 5.1 V | - | Outputs the voltage of the pressure sensor (urea pump). |
| Reductant Pump Speed | Urea pump speed | Min.: 0 rpm, Max.: 65535 rpm | - | Outputs the pump motor speed. |
| Reductant Pump Duty | Urea pump control duty ratio | Min.: 0%, Max.: 255% | - | Outputs the duty ratio of the pump motor. |
| Reductant Pump Current | Operation current of urea pump | Min.: 0 A, Max.: 10.2 A | - | Outputs the current of the pump motor. |
| Reductant Pump Control Mode | Urea pump control mode status | Stop / Heating / Test / Filling / Pressure Rising / Pressure Keep / Purge / Service Mode | - | Outputs the urea pump control mode. |
| Reductant Injector Duty Ratio | Urea Injector assembly control duty | Min.: 0%, Max.: 255% | - | Active Test item [Reductant Injector Duty Ratio] support data. |
ACTIVE TEST
Using the GTS to perform Active Tests allows actuator to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Urea Selective Catalytic Reduction / Active Test.
Perform the Active Test.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Control the Reductant Injector Duty Ratio | Activates the urea injection assembly | 0 to 255% | Test is possible when the following conditions are met:
·
Ignition switch ON. ·
Engine is stopped. |
UTILITY
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Utility.
Perform the Utility according to the GTS screen instructions.
| Tester Display | Usage | Time to usage | Diagnostic Note |
|---|---|---|---|
| Reductant Injection | To confirm whether urea injector assembly and urea solution pipe are operating normal. | ·
When inspection of urea injector assembly. ·
When inspection of urea solution pipe. |
Test is possible when the following conditions are met:
·
Ignition switch ON. ·
Engine is stopped. ·
Urea solution quality is normal. ·
Battery voltage is normal. ·
Urea solution level is more than the rated value. ·
Urea solution temperature is not low. |
| Pressure Rising Diagnosis (Leak Test) | To confirm urea solution pressure rising, perform retention and whether urea solution leakage has occurred. | ·
When inspection of urea pump. ·
When inspection of urea solution pipe. |
|
| Injector Refresh | Perform urea solution pneumatic transportation and vacuum, so that the injector refresh from stuck condition. | When stuck urea injector assembly. | |
| Reductant Pump Speed Check | To confirm whether urea pump is operating normal. | ·
When inspection of urea pump. ·
When inspection of urea solution pipe. |
|
| Reductant Discharge | To confirm if there is no clogging in urea solution pipe. | ·
When inspection of urea pump. ·
When inspection of urea solution pipe. |