89463D
1.INSTALL NO. 2 NITROGEN OXIDES SENSOR
| *a | Torque Wrench Fulcrum Length |
Using SST, install the No. 2 nitrogen oxides sensor.
Replace with a new part if it is dropped or if it receives a strong impact.
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 255 mm (10.0 in.)): 44.7 N*m (456 kgf*cm, 33 ft.*lbf)
Connect the No. 2 nitrogen oxides sensor with the 2 bolts.
Connect the connector to the No. 2 nitrogen oxides sensor.
Attach the 3 clamps.
89463C
2.INSTALL NO. 1 NITROGEN OXIDES SENSOR
| *a | Torque Wrench Fulcrum Length |
Using SST, install the No. 1 nitrogen oxides sensor.
Replace with a new part if it is dropped or if it receives a strong impact.
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 255 mm (10.0 in.)): 44.7 N*m (456 kgf*cm, 33 ft.*lbf)
Connect the No. 1 nitrogen oxides sensor with the 2 bolts.
Connect the connector to the No. 1 nitrogen oxides sensor.
Attach the 4 clamps.