77840A
1.DISCONNECT UREA TUBE WITH HEATER ASSEMBLY
Check for dirt or mud on the urea injector assembly and around the urea tube connector before disconnection. Clean if necessary.
In order to prevent the urea injector assembly interior portion from drying, perform installation and removal work as quickly as possible.
Disconnect the urea tube with heater assembly from the urea injector assembly.
|
Lift Up |
Detach the lock claw by lifting up the cover.
|
Pinch |
|
Pull |
Pinch the retainer of the urea tube connector, and then pull the urea tube connector off of the urea tube with heater assembly.
If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the urea tube connector.
Be sure to disconnect the urea tube connector by hand.
Check for foreign matter in the urea injector assembly and around the urea tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea injector assembly and urea tube connector.
Put the urea injector assembly and urea tube connector ends in plastic bags to prevent damage and foreign matter contamination.
23720
2.REMOVE UREA INJECTOR ASSEMBLY
Disconnect the connector from the urea injector assembly.
Detach the clamp and disconnect the wire harness.
Remove the 3 nuts, urea injector assembly and gasket from the No. 1 exhaust pipe converter assembly.
Slide the 2 hose clamps and disconnect the No. 6 water hose and No. 7 water hose from the urea injector assembly.