N04C-WA EMISSION CONTROL  UREA PUMP  INSPECTION  


PROCEDURE

Hide 77871A 1.INSPECT UREA PUMP

a.

Inspect the level sensor.

i.
A451109C02
0.49,2.281 0.656,2.281 0.656,2.281 1.229,2.5 true 0.552,3.854 0.719,3.854 0.719,3.854 1.219,3.583 true 2.063,1.479 2.063,1 true 2.042,0.698 2.25,0.188 2.25,0.188 2.448,0.188 true 0.229,0.177 0.427,0.385 0.198,0.208 10 false *a 0.302,2.188 0.49,2.385 0.188,0.198 10 false *b 0.365,3.75 0.552,3.958 0.188,0.208 10 false *c 1.958,1.51 2.313,1.698 0.354,0.188 10 false LVU 2.49,0.104 2.844,0.292 0.354,0.188 10 false ELU
*a Component without harness connected
(Urea Pump)
*b Upper
*c Lower


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
14 (LVU) - 6 (ELU) Float is up 85.90 to 89.94 kΩ
Float is down 1.40 to 1.46 kΩ




b.

Inspect the tank heater.

i.
A355506C15
1.385,1.198 1.719,1.698 1.719,1.698 1.885,1.698 true 0.51,1.688 0.677,1.688 0.677,1.688 0.927,1.188 true 0.177,0.156 0.365,0.365 0.188,0.208 10 false *a 0.219,1.604 0.521,1.792 0.302,0.188 10 false HTT 1.938,1.625 2.396,1.823 0.458,0.198 10 false EHTT
*a Component without harness connected
(Urea Pump)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
9 (HTT) - 11 (EHTT) 25°C (77°F) 1.36 to 1.52 kΩ




c.

Inspect the temperature sensor.

i.
A355506C14
1.229,0.969 1.448,0.469 1.448,0.469 1.615,0.469 true 0.885,0.979 0.667,0.5 0.667,0.5 0.5,0.5 true 0.177,0.167 0.396,0.375 0.219,0.208 10 false *a 0.188,0.406 0.51,0.604 0.323,0.198 10 false THU 1.667,0.385 2.125,0.583 0.458,0.198 10 false ETHU
*a Component without harness connected
(Urea Pump)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (THU) - 2 (ETHU) 20°C (68°F) 2.47 to 2.56 kΩ
30°C (86°F) 1.69 to 1.75 kΩ




d.

Inspect the pump motor.

i.
A355506C13
2.531,0.969 2.75,0.469 2.75,0.469 2.917,0.469 true 2.198,0.969 1.979,0.49 1.979,0.49 1.813,0.49 true 2.208,1.198 2,1.688 2,1.688 1.833,1.688 true 2.542,1.188 2.719,1.688 2.719,1.688 2.875,1.688 true 0.156,0.198 0.344,0.417 0.188,0.219 10 false *a 1.344,0.406 1.802,0.615 0.458,0.208 10 false UPMU 2.958,0.385 3.417,0.594 0.458,0.208 10 false UPMV 1.375,1.604 1.844,1.813 0.469,0.208 10 false MGND 2.917,1.604 3.427,1.813 0.51,0.208 10 false UPMW
*a Component without harness connected
(Urea Pump)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
7 (UPMU) - 8 (UPMV) 20 to 30 °C (68 to 86°F) 0.35 to 0.43 Ω
7 (UPMU) - 16 (UPMW)
8 (UPMV) - 16 (UPMW)
7 (UPMU) - 15 (MGND) Always 10 kΩ or higher
8 (UPMV) - 15 (MGND)
16 (UPMW) - 15 (MGND)


If the result is not as specified, replace the urea pump.